400 Series Oven Planning Notes
,QVWDOODWLRQVLGHE\VLGH
ࣞ%2%6%0
ó¼ࡓࡘ&0
Applies to BO/BX/BS/BM/CM/DV/
WS
General notes
Necessary air openings
on the door edges
Installation behind kitchen
cabinet doors
Appropriate measures must be taken
to prevent these types of doors
from closing when the appliance is
heating or while it is cooling down (fan
operation). Please check your local
regulations.
Installation side-by-side
When appliances are installed side
by side, the clearance between
the appliances must be at least ⅜"
(corresponds to the standard outside
measurement of the cabinet opening
of 23 ⅝" or 30"). For best possible
door opening, the door hinges need to
be placed outside in order to use the
full available door opening angle. (see
picture to the right).
Please note: When Sabbath mode is
engaged, the automatic door release
is deactivated.
Gaggenau 400 series ovens are
supplied with fresh air for cooling at
the top edge and side edges of the
door. Hot air is blown out at the door
bottom edge. Combi-steam ovens and
Combi-microwave ovens have the air
inlet at the side edges of the door and
the hot air and steam outlets at the top
edge of the door.
In order to prevent appliances from
overheating and to ensure that they
cool down as required after operation,
appropriate minimum cross sections of
free space must be maintained from
kitchen cabinet edges.
The measurements given in the
drawing apply to all appliances. The
following must also be observed:
The area above the appliances
BS:
No other electrical appliances should
be installed above the BS Combi-
steam oven. It is recommended that
a horizontal handle is not fitted on
cabinet above the BS. Where an
edge of a kitchen cabinet protrudes
more than ¹³⁄₁₆" in front of the edge
of the cabinet opening, the edge
of the kitchen cabinet panel must
be steam resistant as is the case
above a dishwasher. Steam may
possibly penetrate into the shelf
compartment.
The area below the appliances
DV/WS:
It must be ensured that there is
sufficient access to the lower edge
of the vacuuming drawer and warming
drawer, if the thickness of the kitchen
cabinet door is greater than ¹³⁄₁₆" (20
mm) in front of the cabinet opening.
Planning notes for the recommended installation of 400 series ovens
Installation side-by-side
Air openings on the door edges above/below
Numbers indicated
inside parenthesis ( ) = mm
www.gaggenau.com/us
Revised: 31 March 2020