400 Series Oven Planning Notes
.
When installing a 400 series Vario
cooling appliancenext to a 400 series
BO/BM/BS/CM appliance, a minimum
lateral distance of 1 ³⁄₁₆" (30 mm) is
required.
Installation in corners Door clearance at the sides
When the pull-out drawer is used, a
larger door opening angle of 7 ⅞"
is required. For all other situations,
3 ¹⁵⁄₁₆" is recommended. Where there
are smaller side clearances down to
a minimum of 1 ¹⁵⁄₁₆", restrictions in
handling hot baking trays should be
expected and the user-friendliness
of the side-opening door can not be
taken for granted.
At the sides
In situations where kitchen cabinet
doors are thicker, or where sidewalls
protrude up to 1 ⁵⁄₁₆" from the front of
the edge of the cabinet opening, the
minimum distance on the hinge side
is sufficient for the air supply and a
door opening angle of 120°. Above
that, a distance of ⅜" or even more
is required.
The handle side may, if required, be
covered by a side panel provided that
the minimum distance is maintained.
Installation in corner situation
Air openings on the door edges
Installation next to cooling appliances
Numbers indicated
inside parenthesis ( ) = mm
www.gaggenau.com/us
Revised: 31 March 2020