Ventilation
To assure that the appliance works correctly, the cooktop
MUST be sufficiently ventilated.
Since the ventilation in the lower section of the appliance
requires a sufficient supply of fresh air, the cabinet must
be designed accordingly. The following is required for
this:
ʑ A minimum clearance between the rear of the
cupboard and the kitchen wall, and between the
surface of the worktop and the upper area of the
drawer.
ʑ An opening at the top to the rear of the cupboard.
ʑ If the minimum clearance of
25
/
32
inch (20 mm) is not
provided at the rear of the cupboard, you must create
an opening on the underside.
ʑ If the inside of the cupboard is no wider than
29
1
/
2
inch (750 mm), make cutouts in the side panels.
Note: If the appliance is installed in an island unit or
another installation that is not described here, you must
ensure that the cooktop is sufficiently ventilated.