8 - PURIFIER REGENERATION
IMPORTANT : Regenerate the purifier at the intervals listed
below:
HARDNESS °F 8 LITRE PURIFIER 12 LITRE PURIFIER
From 00 to 20 re
g
eneration after 1100 l. re
g
eneration after 1600 l
From 21 to 30 re
g
eneration after 850 l. re
g
eneration after 1250 l.
From 31 to 40 re
g
eneration after 650 l. re
g
eneration after 950 l.
From 41 to 60 re
g
eneration after 450 l. re
g
eneration after 650 l.
- place the empty 2 litre container under pipe E.
- shift levers C and D from left to right as shown in fig.8.2 and
remove the cover by loosening knob G, pour in 1.5 kg of
sodium chloride (coarse cooking salt) into the 8-litre purifier
and 2 kg into the 12-litre type.
- Replace the lid and shift lever from right to left as shown in
fig.8.3 and allow the salted water to drain out of pipe F until
the water is fresh.
- Shift lever D from right to left as shown in fig.8.4
NB: These regeneration instructions are valid only
providing the purifier is as that indicated in the figures.
Should it fail to correspond proceed as indicated in the
instructions attached to the purifier itself.