Users Manual

70 03-2019 0193 00
mixEr
For appliances that dispense instant bever-
ages, remove the components as follows:
1. Disconnect the hoses from the mixer
connections.
2. Turn the mixer locking ring anticlockwise
and remove the mixer.
Take special care to fully lock it when
reassembling it;
3. Separate the instant powder funnel, the
powder tray and water funnel.
5
4
6
3
2
1
7
Fig. 46
1. Instant powder funnel
2. Instant powder tray
3. Water funnel
4. Mixer fan
5. Instant beverage hose connection
6. Mixer locking ring
7. Brushes for cleaning hoses and “ splash zone
4. Remove the fans: block the disk fitted
on the motor mixer shaft with one finger,
then unscrew the mixer fan.
Fig. 47
5. Dip the parts for approx. 20 minutes in a
recipient containing the previously-pre-
pared sterilising solution.
Wash all the components with sterilising
products (follow the dosage indicated
by the manufacturer), being careful to
mechanically remove the residues and
visible films using brushes and swabs if
necessary.
6. Verify that the motor mixer's sealing gas-
ket is not torn and has not lost its elasticity.
7. Reassemble the powder drawers and
the powder funnels after having carefully
rinsed and dried them.
8. Place the mixer back into position and
make sure that the water funnel has been
correctly inserted.
Fig. 48
After reassembling the components, it

Wash the mixer and add a few drops of the
sanitising solution into the various funnels
and rinse thoroughly to remove any resi-
dues from the solution that has been used.