Lubricating the brew group
In order to ensure the perfect performance of the machine, it is necessary
to lubricate the brew group. Refer to the following table for the frequency of
lubrication.
Frequency of use
Number of beverages prepared
daily
Lubrication
frequency
Low 1-5 Every 4 months
Regular 6-10 Every 2 months
High >10 Every month
1 Turn off the appliance and disconnect the power cord.
2 Remove the brew group and rinse it using lukewarm water - see the “Cleaning
the brew group under running water” chapter.
3 Apply a thin layer of the lubricant provided around the insertion pin on the
lower part of the brew group.
4 Applyathinlayeroflubricanttotheguides,onbothsides(seegure).
5 Reinsert the brew group - see the “Reinserting the brew group” chapter.
Note: you can use the lubricant tube multiple times.