Quick Installation Guide

Pub. 42004-538AQG
HUBBCOM GRC600 Remote Station Quick Installation Guide Page 3 of 5
C:\Users\PDrenning\AppData\Local\Microsoft\Windows\INetCache\Content.Outlook\PB6OVX22\HUBBCOM GRC600 Remote Station Quick Installation
Guide.docx
10/19
6. Assemble the front cover to the mounting plate and secure with the two security screws removed from the
bottom of the station in Step 2.
7. Tighten the screws to 35 inlb.
Wiring
HUBBCOM Remote stations are equipped with screw connection terminal blocks that accept 2616 AWG wires.
Power
Complete the following steps to terminate the input power cable at terminal block TB1:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 1).
Table 1.
Purpose
Label
Power
Power +
+
Ethernet
Complete the following steps to terminate the Ethernet cable at terminal block TB2:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 2).
Table 2.
Purpose
Label
Ethernet
A+
Ethernet
A-
Ethernet
B+
Ethernet
C+
Ethernet
C-
Ethernet
B-
Ethernet
D+
Ethernet
D-
Output Contacts
Complete the following steps to terminate the output connections at terminal block TB3:
1. Install appropriately sized ferrules onto the wire ends.
2. Install each wire into the correct terminal (See Table 3).