Installation Instructions Model#GL1FR24ASSAGN nce, using rom ted ore e e n it is at e for cturing ng. moke Thank you for purchasing a Galanz product. Please read this manual carefully for correct usage and safety, and keep for future reference. For service, support and warranty information, call 800-562-0738. ©2019 Galanz Americas Limited Company @2019 Galanz Americas Limited Company.
CONTENT CONTENT RANGE SAFETY........................................................................................................................... 2 INSTALLATION REQUIREMENTS ............................................................................................. 4 TOOLS AND PARTS.......................................................................................................... 4 LOCATION REQUIREMENTS.........................................................................................
RANGE SAFETY YOUR SAFETY AND THE SAFETY OF We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. DANGER FPO An imminently hazardous situation. You could be killed or seriously injured if you don’t immediately follow instructions. WARNING A potentially hazardous situation which, if not avoided, could result in death or serious bodily injury.
RANGE SAFETY RANGE SAFETY WARNING: Gas leaks cannot always be detected by smell. Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the “What to do if you smell gas” instructions.
INSTALLATION REQUIREMENTS TOOLS AND PARTS PARTS SUPPLIED Check that all parts are included. A Tape measure Flat-blade screwdriver Phillips screwdriver Level Cordless electric Drill Hammer Wrench or pliers Pipe wrench 10" Adjustable Wrenches (2) 3⁄8" nut driver ¼" nut driver 7 mm combination wrench using E 1⁄8" (3.
INSTALLATION REQUIREMENTS Gas Supply Line Kit (Supply Line and 2 adapters) INSTALLATION REQUIREMENTS LOCATION REQUIREMENTS VENTILATION FPO TEMPERATURE IMPORTANT: This oven has been designed in accordance with the nce, requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194F (90°C) Some cabinet and building materials are not designed to withstand using the heat produced by the oven for baking and self-cleaning.
INSTALLATION REQUIREMENTS DIMENSIONS Back of Range A A Gas Line from Range 5.9" (15 cm) Min. 30" (76 cm) Min. B Power Cord FPO B A E D Power Supply IMPORTANT: An electrical outlet in the floor, may be either recessed or surface mounted, but an electrical outlet in the wall must be recessed to make the connection. For Direct Wiring, the electrical box should be mounted to the wall. C B A. Depth w/ D. Height to top E. Height B. Width C. Depth Handle of Cooktop Overall 251⁄5" (64.
INSTALLATION REQUIREMENTS INSTALLATION REQUIREMENTS *NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper. 30" (76.2 cm) minimum clearance between the cooking and the bottom of an uncovered wood or metal cabinet.
INSTALLATION REQUIREMENTS A copy of the above code standards can be obtained from: National Fire Protection Association 1 Batterymarch Park Quincy, MA 02169-7471 CSA International 8501 East Pleasant Valley Road Cleveland, OH 44131-5575 FPO A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A timedelay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observe all governing codes and ordinances. GAS SUPPLY LINE IMPORTANT: This installation must conform with all local codes and ordinances. In the absence of local codes, installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 - latest edition or CAN/CGA B149 – latest edition. Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range location.
INSTALLATION INSTRUCTIONS GAS PRESSURE REGULATOR Flexible metal appliance connector: FPO A ½" (1.3 cm) male pipe thread is needed for connection to the female pipe threads of the inlet to the appliance pressure regulator. Do not kink or damage the flexible metal tubing when moving the range. Rigid pipe connection: The rigid pipe connection requires a combination of pipe fittings to obtain an in-line connection to the range. The rigid pipe must be level with the range connection.
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Line pressure testing at 0.5 psi gauge (14" WCP) or lower The range must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 0.5 psi (3.5 kPa). FPO Thank you for purchas ing a G alanz produc t. P leas e read this manual c arefully for c orrec t us age and s afety, and keep for future reference.
INSTALLATION INSTRUCTIONS STEP 1 - UNPACK RANGE WARNING Excessive Weight Hazard Use two or more people to move and install range. Failure to do so can result in back or other injury. FPO 1. Remove shipping materials, tape and film from the range. Keep cardboard bottom under range. Do not dispose of anything until the installation is complete. 2. Remove oven racks and parts package from oven and shipping materials. 3. To remove cardboard bottom, first take four cardboard corners from the carton.
INSTALLATION INSTRUCTIONS STEP 3 - INSTALL ANTI-TIP BRACKET INSTALLATION INSTRUCTIONS B A A Backsplash -Back Edge B Backsplash - Bottom Edge FPO 3. Insert the two screws (one on each side) through the back edge of the backsplash and into the cooktop. Tighten completely. IMPORTANT: This insert replaces the directions for “Installing the Anti‑Tip Bracket” and “Installing the Range” found in the 24" Electric Free‑Standing Range Installation Instructions for Models GL1FR24ASSAGN.
INSTALLATION INSTRUCTIONS 3. Using the anti-tip bracket as a template, mark the two holes for either a Floor Wood, Floor Concrete, or Wall installation, as shown. 1. Remove the anti-tip bracket and two screws (provided) from the parts bag. A B A C Concrete Floor Holes B Anti-tip Bracket B A Distance from Adjacent Cabinet (³⁄₈" to ¹⁄₂" [0.95 to 1.27 cm]) B Wall Holes A 16 x 15⁄8 " Screws (2) FPO E D Wood Floor Holes DC E Rear Range Foot 4. Drill two pilot holes where marked.
INSTALLATION INSTRUCTIONS STEP 4 - MAKE GAS CONNECTION A INSTALLATION INSTRUCTIONS B WARNING C A Wall B Anti-tip Bracket C Floor 5. Install the anti-tip bracket. Wood FPO Using the two screws (provided) fasten the anti-tip bracket to the floor or wall. NOTE: The screw must enter wood or metal. Concrete Insert the sleeve anchor into the drilled holes and then insert the lag bolts through the anti-tip bracket and into the floor or wall.
WARRANTY REGISTRATION INSTALLATION INSTRUCTIONS INSTALL ANTI-TIP BRACKET 1. Apply pipe-joint compound made for use with LP gas to the male threads of adapter C . 2. Insert adapter C into outlet of the gas pressure regulator D , and then tighten using two 10" adjustable wrenches. Be sure flow arrow on regulator is pointing up toward the range gas inlet pipe. 3. Install washer B in female end of adapter C , and then connect adapter C to range gas inlet pipe A via compression fitting and tighten.
INSTALLATION INSTRUCTIONS COMPLETE CONNECTION STEP 6 - INSTALL RANGE INSTALLATION INSTRUCTIONS 1. Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe. Test all connections by brushing on an approved noncorrosive leak-detection solution. If bubbles appear, a leak is indicated. Correct any leak found.
INSTALLATION INSTRUCTIONS STEP 7 - LEVEL THE RANGE (IF NEEDED) INSTALLATION INSTRUCTIONS 3. Slowly attempt to tilt the range forward. If you encounter immediate resistance, the range foot is engaged in the anti-tip bracket. Go to Step 7. 4. If the rear of the range lifts more than ½" (1.3 cm) off the floor without resistance, stop tilting the range and lower it gently back to the floor. The range foot is not engaged in the anti-tip bracket.
INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Check Operation of Standard Surface Burners: To adjust standard burner: Push in and turn each control knob to the “ICON” position. The flame should light within 4 seconds. The first time a burner is lit, it may take longer than 4 seconds to light because of air in the gas line. IMPORTANT: Adjustments must be made with two other burners in operation on a medium setting.
WARRANTY REGISTRATION GAS CONVERSION WARNING 24" Burner and Orifice Characteristic Table Explosion Hazard Use a new CSA International approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column. Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and authorized service personnel.
GAS CONVERSION STEP 1 - ADJUST THE REGULATOR GAS CONVERSION A Opening in grate for wok ring (provided) is located over left front burner. a A IMPORTANT: Disconnect all electrical power, at the main circuit breaker or fuse box. Shut off the gas supply to the range by closing the manual shut-off valve. 1. Unscrew the regulator cap with the wrench. A Regulator Cap A Tools Needed for Conversion: Wrench 7 mm Nut Driver Safety Glasses Small Flat-head Screwdriver 2.
WARRANTY REGISTRATION GAS CONVERSION 3. Turn the retainer pin upside down and replace it into the regulator cap. It is now positioned for use with LP gas. A Retainer Pin IMPORTANT: Carefully read and observe each orifice label for correct location. See the Burner Chart earlier in this section. GAS CONVERSION A STEP 2 - CHANGE BURNER ORIFICES NOTE: First remove all orifices and then start replacing them. This will help avoid the possibility that some may not be replaced. 1.
GAS CONVERSION GAS CONVERSION 3. Install the proper orifices in the exact locations as noted in the previous graphic. 4. Replace the burner bases, heads, caps and top grates. Make sure burner caps are properly seated on the burner head. Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on.
WARRANTY REGISTRATION GAS CONVERSION STEP 4 - TESTING FLAME STABILITY If the low flame needs to be adjusted: A OFF B MAX B Control Knob Stem Test 1 - Turn the knob from “MAX” to “MIN” quickly. If the upper row of flames goes out at this setting, increase the flame size and test again. Test 2 - With the burner on “MIN”, open and close the cabinet door under the cooktop. If the air currents created by the door moving extinguish the flame, increase the flame height and test again.
GAS CONVERSION ABNORMAL OPERATION GAS CONVERSION ANY OF THE FOLLOWING ARE CONSIDERED TO BE ABNORMAL OPERATION AND MAY REQUIRE SERVICING: Yellow tipping of the hob burner flame. Sooting up of cooking utensils. Burners not igniting properly. Burners failing to remain lit. Burners extinguished by oven door. Gas valves, which are difficult to turn.