Installation Guide

Thank you for purchasing a G alanz produc t. P lease read this manual c arefully for correct us age and safety,
and keep for future reference. For service, support and warranty information, call 800- 562- 0738.
FPO
INSTALLATION INSTRUCTIONS
10
INSTALLATION INSTRUCTIONS
GAS PRESSURE REGULATOR
The gas pressure regulator supplied with this range must be used.
The inlet pressure to the regulator should be as follows for proper
operation:
GAS SUPPLY PRESSURE TESTING
Gas supply pressure for testing regulator must be at least 1" Water
Column Pressur (WCP) above the manifold pressure shown on the
model/serial rating plate.
If local codes permit, a new CSA design-certified, 4 - 5 ft (122 -
152.4 cm) long, ½" (1.3 cm) or ¾" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
A ½" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the
range.
The rigid pipe connection requires a combination of pipe fittings to
obtain an in-line connection to the range. The rigid pipe must be level
with the range connection. All strains must be removed from the
supply and fuel lines so range will be level and in line.
Flexible metal appliance connector:
Rigid pipe connection:
Minimum pressure: 5" Water Column Pressure (WCP)
Maximum pressure: 10.5" WCP
Natural gas:
Minimum pressure: 8" WCP
Maximum pressure: 13" WCP
Contact local gas supplier if you are not sure about the inlet pressure.
LP gas:
Input ratings shown on the model/serial rating plate are for elevations
up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate
of 4% for each 1,000 ft (304.8 m) above sea level (not applicable for
Canada).
Burner Input Requirements
The range and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that
system at test pressures in excess of 0.5 psi (3.5 kPa).
Line pressure testing above 0.5 psi gauge (14" WCP)