Installation Guide
22
OPERATION INSTRUCTIONS
WARRANTY REGISTRATION
GAS CONVERSION
GAS CONVERSION
IMPORTANT: Carefully read and observe each orifice label for
correct location. See the Burner Chart earlier in this section.
STEP 2 - CHANGE BURNER ORIFICES
A
Retainer Pin
A
Orifices
Turn the retainer pin upside down and replace it into the
regulator cap. It is now positioned for use with LP gas.
3.
Remove the burner grates, burner caps and burner heads.
Using a 7 mm nut driver, remove the burner orifices.
1.
2.
Screw the regulator cap back into the regulator and
reattach the regulator to the nipple and flare union.
4.
A
NOTE: First remove all orifices and then start replacing
them. This will help avoid the possibility that some may
not be replaced.
Triple Ring Burner
5 Orifices
Auxiliary Burner
Semi-Rapid Burner
Rapid Burner
1 Orifice Each
A