This range is equipped with an electronic ignition system that will not
operate if plugged into an outlet that is not properly polarized.
If codes permit and a separate ground wire is used, it is recommended
that a qualified electrical installer determine that the ground path is
adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is
required. A timedelay fuse or circuit breaker is also recommended. It
is recommended that a separate circuit serving only this range be
provided.
Electronic ignition systems operate within wide voltage limits, but
proper grounding and polarity are necessary. Check that the outlet
provides 120-volt power and is correctly grounded.
This gas range is not required to be plugged into a GFCI
(Ground-Fault Circuit Interrupter) outlet. It is recommended that you
not plug an electric spark ignition gas range or any other major
appliance into a GFCI wall outlet as it may cause the GFCI to trip
during normal cycling.
Performance of this range will not be affected if operated on a
GFCI-protected circuit. However, occasional nuisance tripping of the
GFCI breaker is possible due to the normal operating nature of
electronic gas ranges.
The wiring diagram is located on the back of the range in a
clear plastic bag.
NOTE: The metal chassis of the range must be grounded in
order for the control panel to work. If the metal chassis of
the range is not grounded, no keypads will operate. Check
with a qualified electrician if you are in doubt as to whether
the metal chassis of the range is grounded.
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas
pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion or fire.
WARNING
Explosion Hazard
GAS SUPPLY REQUIREMENTS