Note: Once the desired High Shelving filter is selected, the “PM3” can then be used to select the
desired GAIN and when the GAIN is set at a value different from 0.0dB, then the filter type cannot
be changed until this GAIN is returned to 0.0dB.
Once in the High Shelving Filters edit screen all the filters parameters can be modified using the
NAV/PM1, “PM2” and “PM3” encoders for editing the Filters Low Cut Frequency, Filters Order
and Gain.
The Lo Cut Frequency of the High Shelving Filter can be edited using the “NAV/PM1” encoder, the
Filters Order can be adjusted by the “PM2” encoder and the Gain the “PM3” encoder:
Lo Cut Frequency: the selectable frequencies range is from 20Hz to 20kHz in steps of 1/24 of
an Octave and can be adjusted by rotating the “NAV/PM1” encoder.
High Shelving Order: the selectable High Shelving Filters range can be selected between the
1st (Lo-1st.) and the 2nd (Lo-2nd.) one.
Gain: the selectable range of the Gain is from -15dB to +15dB in steps of 0.5 dB and can be
adjusted by rotating the “PM3” encoder.
Note1: Once the desired options have been selected using the 3 encoders, they are automatically
saved as current and stored in the DS-EQ230 system status once leaving the page.
Note2: To exit this page, push the “ESC” button.
Volume page - from this screen it is possible to set the Equalizers Channels Output Level from
-12dB to +6dB, press ENTER an arrow will appear on the left of the screen “->” then use the
PM1” or “PM2” buttons.
The value set on this screen will only affect the output level of the selected Equalizers Channel.
The following is an example screen for the “Volume” page where the Gain of the Equalizers
Channel A (named Left) is set to +0.0dB.
DPA-240A
1x2 WAY X-OVER
DPA-240A
1x2 WAY X-OVER
OutputA Left Volume
-> Volume = + 0.0dB
23