Initialisation
Initialising with the CardaxFT URI
The CardaxFT URI must be allocated a unique unit address which is set up at the
CardaxFT URI and at the Command Centre FT Server. Refer to the CardaxFT Universal
Reader Interface Installation Note and the Command Centre FT documentation.
Note: When configuring Command Centre FT you will need to know the plug (P1
or P2) to which the Prox 125 reader is connected.
Initialising with the Cardax IV URI
Type of Door Lock
Depending on the type of lock fitted to the door that the reader is controlling, you will
need to initialise the URI with the door either closed or open.
If you initialise the URI with the door held open, it sets the door to unlock and remains
unlocked until the door is fully closed again. If you initialise the URI with the door closed
it sets the door to unlock and resets to lock as soon as the door is opened.
Note: If you are installing the Prox 125 reader to control a turnstile you should
consult the turnstile manufacturer for details of the locking mechanism used.
Push-Button Exit
If the door has a push button exit, ensure the URI Exit terminal has the push-button fitted
and correctly terminated with a 10 kW resistor before you power on.
Check Software Version
You should check the URI software version to ensure it is correct for your installation.
The software version number is written on the label of the EPROM mounted at the
bottom right of the URI processor board.
URI software versions that are compatible with the Prox 125 reader are shown below:
Software Reader Type
vW6.1x series or later One door Cardax Prox or Swipe Readers
vW7.1x TC series or later URI Special Options : Cardax Turnstile format
vW9.1x series or later Two door Cardax Prox or Swipe Readers
Note : The vW6.xx and vW9.xx series will have one of the following suffixes:
GT = 2 wire modem connection