User's Manual

Part number 3E1100 R12 15
June 2007
Setting the Dip Switches
Set DIPSW1 as follows:
Switches On Off
1
2
3
4
5
6
7
8
1
2
4
8
16
32
Unit
Addresses
Initialise
Normal
2 door software
= keypad on door 2
1 door software
= liftcar reader
2 door software
= no keypad on door 2
1 door software
= door reader
Set DIPSW2 as follows, where 0 = OFF and 1 = ON:
URI Software
vW6.xx
and
vW9.xx
vW3.61 to vW3.67
and
vW4.74 to vW4.81
Reader
DIPSW2
12345678
DIPSW2
12345678
Prox Mifare Series (Teardrop) reader
only, no authorised exit
00000000 00011000
Prox Mifare Series (Teardrop) reader
only, with authorised exit
00000100 00011100
Prox Mifare Series (Teardrop) reader
with external keypad and no
authorised exit.
00000011 10011011
Prox Mifare Series (Teardrop) reader
with external keypad and authorised
exit.
00000111 10011111
For further details on software versions refer to Check Software Version
earlier in this Installation Note.