User's Manual

20
Memory Counter
The Memory counter is only applicable when in Memory mode.
Once the memory is full, the Memory counter displays FULL. Note
however that even when the memory is full, if a new EID tag is read
the number of tag reads in the current session still increases (in the
example shown, 28 is the number of tag reads).
Note: Once the memory is full in Memory mode, each time you
read a new EID tag, by default, the oldest EID tag data is deleted
and the newest EID tag data is stored. This can be changed using the ‘Overwrite’ setting
in Confi gurator. For further details refer to the SmartReader HR
3 Confi gurator User
Manual.
The Memory counter is returned to 0 by downloading tag data using MyScale Pro. For
further details refer to the MyScale Pro for SmartReaders User Manual.
Session Limit
The SmartReader has a session limit of 100. While the current
session number cannot be identifi ed, if you reach the session limit
the following screen displays:
If this occurs, you should immediately download the sessions using
MyScale Pro. However, you can continue to read and store tags to
the current session, providing there is suffi cient space within the
current session, or it has been confi gured to allow this. Refer to
the SmartReader HR
3 Confi gurator User Manual.
Non-Memory mode options
Zero count
Single-Click the trigger to reset the number of tags read in the current session. Only
applicable when in Non-memory mode.