SDS
MATERIAL SAFETY DATA SHEET
Manufacturer:BST POWER(SHENZHEN) LIMITED
Date: Dec,2013 VER:3.0
Page 2 of 10
Dimethyl carbonate
616-38-6
Lithium
hexafluorophosphate
21324-40-3
sensitizer;eye;skin &respiratory
irritant
Section 3. Hazardous Identification
Lithium Ion batteries described in this MSDS data sheet are hermetically sealed and designed to withstand
temperatures and pressures encountered during normal use. Under normal conditions of use, there is no
physical danger of ignition, explosion or chemical danger of hazardous materials leakage. The materials
contained in this battery may only represent a hazard if the integrity of the battery is compromised or if the
battery is mechanically, thermally or electrically abused.
Caution: Do not open or disassemble the batteries. Do not expose the batteries to fire or open flame. Do
not mix batteries of varying sizes or chemistries. Do not short circuit, puncture, incinerate, crush, over-charge,
over discharge, or expose the batteries to temperatures above the declared limit. Abuse of the batteries will result
in the risk of fire or explosion, which could release hydrogen fluoride gas.
Human Health Hazard: Electrolyte may irritate skin and eyes. Electrolyte steam has an anesthesia
action and irritates the respiratory tract.
Section 4. First Aid Measures
inhalation:
If contents of an opened cell are inhaled, remove source of contamination or move
victim to fresh air .Obtain medical advice.
Eye contact:
Contact with the contents of an opened cell can cause burns. If eye contact with
contents of an open cell occurs, immediately flush the contaminated eye(s) with
lukewarm, gently flowing water for at least 30 minutes while holding the eyelids
open. Neutral saline solution may be used as soon as it is available. If necessary,
continue flushing during transport to emergency care facility. Take care not to
rinse contaminated water into the unaffected eye or onto face. Quickly transport
victim to an emergency care facility.
Skin contact:
Contact with the contents of an opened cell can cause burns. If skin contact with
contents of an open cell occurs, as quickly as possible remove contaminated
clothing, shoes and leather goods. Immediately flush with lukewarm, gently
flowing water for at least 30 minutes. If irritation or pain persists, seek medical
attention. Completely decontaminate clothing, shoes and leather goods before
reuse or discard.