SDS

MATERIAL SAFETY DATA SHEET
ManufacturerBST POWER(SHENZHEN) LIMITED
Date: Dec,2013 VER3.0
Page 3 of 10
Inhalation:
Contact with the contents of an opened cell can cause burns. If ingestion of
contents of an open cell occurs, NEVER give anything by mouth if victim is
rapidly losing consciousness, or is unconscious or convulsing. Have victim rinse
mouth thoroughly with water. DO NOT INDUCE VOMITING. If vomiting occurs
naturally, have victim lean forward to reduce risk of aspiration. Have victim rinse
mouth with water again. Quickly transport victim to an emergency care facility.
Section 5. Fire Fighting Measures:
Flammable Properties
Lithium ion batteries contain flammable liquid electrolyte
that may vent, ignite and produce sparks when subjected
to high temperatures (> 150 °C (302 °F)), when damaged
or abused (e.g., mechanical damage or electrical
overcharge). Burning cells can ignite other batteries in
close proximity.
Suitable extinguishing Media:
Small Fires - Dry chemical, CO
2
, water spray or regular
foam.Large Fires -
Water spray, fog or regular foam.
Move containers from fire area if you can do it without
risk.
Unsuitable extinguishing Media:
Not Applicable
Explosion Data:
Sensitivity to Mechanical Impact:
Extreme mechanical abuse will result in rupture of the
individual battery cells.
Sensitivity to Static Discharge:
Electrostatic discharges imposed directly on the spilled
electrolyte may start combustion.
Section 6. Accidental Release Measures:
Personal Precautions:
As an immediate precautionary measure, isolate spill or
leak area for at least 25 meters (75 feet) in all directions.
Keep unauthorized personnel away. Stay upwind. Keep out
of low areas.
Ventilate closed areas before entering.
Wear adequate personal protective equipment as indicated
in Section 8.
Environmental Precautions:
Prevent material from contaminating soil and from
entering sewers or waterways.
Methods for Containment:
Stop the leak if safe to do so. Contain the spilled liquid
with dry sand or earth. Clean up spills immediately.
Methods for Clean-up:
Absorb spilled material with an inert absorbent (dry sand