User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. General Information
- 3. Mounting
- 3.1 Definition of the Door Hinge (Right or Left Door)
- 3.2 Metallic and Non-Metallic Doors
- 3.3 Dimension Diagrams for Mounting
- 3.4 Door Status Contact
- 3.5 Mounting in Lockers with Non-Metallic Doors
- 3.6 Mounting in Lockers with Metallic Doors
- 3.7 Points to be observed during Installation
- 3.8 Test Installation
- 3.9 Replacement after a Burglary Attempt
- 3.10 Installation of the GAT NET.Controller M/S 7000
- 4. Electrical Connection
- 5. Configuration And Operation
- 5.1 Antenna Adjustment of the GAT NET.Lock 7000
- 5.2 Locker Operation by the Visitor
- 5.3 Restart a Controller GAT NET.Controller S 7000 or GAT NET.Controller M 7000
- 5.4 Delete Configuration Parameters of a Controller (= Reset to Default Settings)
- 5.5 Status Information for the GAT NET.Controller S 7000 and GAT NET.Controller M 7000
- 5.6 GAT Relaxx - Operation Software for GAT NET.Lock 7000 System
- 6. Technical Data
GAT NET.Lock 7000 System
Mounting
14
HB_GAT-NETLOCK7000--US_33
www.gantner.com
3.2 Metallic and Non-Metallic Doors
Because the RFID field of the GAT NET.Lock 7000 is distorted or blocked by metal (e.g. with metallic locker doors),
a cut-out has to be made in metallic locker doors into which the GAT NET.Lock Bolt Set 7200 and the label carrier
can be installed. A specific cut-out for non-metallic doors is not necessary, only a drill hole for the LED field is re-
quired.
Since the reading range of the GAT NET.Lock 7000 is limited, the locker door of non-metallic lockers must not be
too thick. The maximum door thickness of non-metallic doors depends on the RFID technology and data carriers
used.
3.3 Dimension Diagrams for Mounting
3.3.1 Door Width
The minimum door width allowed (measured from the door shackle to the hinge) is 230 mm. If the door is narrower,
the door shackle would hit the locker when the door is being closed.
Figure 3.2 - Minimal door width