User's Manual
Table Of Contents
- 1. INTRODUCTION
- 2. General Information
- 3. Mounting
- 3.1 Definition of the Door Hinge (Right or Left Door)
- 3.2 Metallic and Non-Metallic Doors
- 3.3 Dimension Diagrams for Mounting
- 3.4 Door Status Contact
- 3.5 Mounting in Lockers with Non-Metallic Doors
- 3.6 Mounting in Lockers with Metallic Doors
- 3.7 Points to be observed during Installation
- 3.8 Test Installation
- 3.9 Replacement after a Burglary Attempt
- 3.10 Installation of the GAT NET.Controller M/S 7000
- 4. Electrical Connection
- 5. Configuration And Operation
- 5.1 Antenna Adjustment of the GAT NET.Lock 7000
- 5.2 Locker Operation by the Visitor
- 5.3 Restart a Controller GAT NET.Controller S 7000 or GAT NET.Controller M 7000
- 5.4 Delete Configuration Parameters of a Controller (= Reset to Default Settings)
- 5.5 Status Information for the GAT NET.Controller S 7000 and GAT NET.Controller M 7000
- 5.6 GAT Relaxx - Operation Software for GAT NET.Lock 7000 System
- 6. Technical Data
GAT NET.Lock 7000 System
Mounting
www.gantner.com
HB_GAT-NETLOCK7000--US_33
23
Note: A label is available to cover the LED hole. The label has a transparent (matt) viewing window for the LED
to shine through and can be ordered with a standard GANTNER or customer specific design.
Figure 3.9 - Label carrier with front label
Close the door to test if the locker door can be closed easily and the door shackle inserts into the opening of the
GAT NET.Lock 7000.
3.7 Points to be observed during Installation
Fastening screws:
The GAT NET.Lock 7000 is attached to the locker wall using three screws. Use the correct type of screws depend-
ing on the type of locker material. The screws must not be over tightened and the maximum allowed tightening
torque is 2 Nm.
Mounting of the door shackle:
For fastening the bolt set with the door shackle on the door the correct screws depending on the type of locker ma-
terial must be used. For mounting the GAT NET.Lock BoltSet 7200 use the pan-head metal screws Torx 3.5 x 9.5
mm (included in the scope of supply). The positioning and mounting of the door shackle should be performed after
the final alignment of the lockers on site. As described in the installation instructions, ensure that the bolt set and the
front of the GAT NET.Lock 7000 are parallel to each other.
No retaining devices:
No retaining devices such as springs should be used on the doors as this will prevent the opening function of the
locker doors.
Hinge:
The hinges of the locker door must not be equipped with retaining springs or similar elements. The locker door must
open automatically without resistance when the GAT NET.Lock 7000 unlocks the door.