5. CONFIGURATION AND OPERATION
5.1 Antenna Adjustment of the GAT NET.Lock 7000
The antenna of the GAT NET.Lock 7000 must be adjusted so that an optimal reading range for the RFID data carri-
ers is obtained. The antenna adjustment does not need to be done by hand as the GAT NET.Lock 7000 supports
automatic antenna adjustment via PC software.
The antenna adjustment of a lock is also possible with the MODE button of the Slave Controller, where the lock is
connected (see "4.3.4. LED Signals and Buttons").
Note: The locker door must be closed during the antenna adjustment so that the test conditions meet the later op-
erating conditions.
Proceed with these steps:
- Close all locker doors.
- Press MODE button once.
-> The antenna adjustment is completed in less than 1 second.
5.2 Locker Operation by the Visitor
5.2.1 Lock a Locker
In order to use an unused locker (i.e. locking a locker), the door must be pressed shut so that the door shackle
moves into the GAT NET.Lock 7000. While the door is pressed shut the user must hold their data carrier next to the
reading field on the locker door. The GAT NET.Lock 7000 reads the data carrier then communicates with the slave
and master controllers and if the data carrier (i.e. the user) is allowed to use the locker, a command is sent so that
the GAT NET.Lock 7000 will lock the locker.
A push button at the front of the GAT NET.Lock 7000 lock detects if the locker door is closed or not. This feature al-
lows indication of the locker status on a PC running locker system software.
5.2.2 Unlock and Open a Locker
When a user wants to open a locker, the user must identify himself at the lock with his RFID data carrier. As soon
as the user holds his data carrier to the RFID scan field the GAT NET.Lock 7000 reads the data carrier, communi-
cates with the slave and master controllers and if the data carrier (i.e. the user) is allowed to open the locker, a
command will be sent so that the GAT NET.Lock 7000 will unlock the locker.