User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGICĀ®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Mounting the GAT Access 6100 Terminals
16
HB_GAT-ACCESS6100--EN_12
www.gantner.com
Mounting the Device Upper Part
Once the connection cables are terminated, the device back part and upper part are connected together via a
connection cable (already connected in the upper part) and the two parts are fixed together.
Figure 2.2 - Connection and mounting of the device upper part
Notes:
1. Check the socket in the device back part (circled in figure 1). Dirt, dust and humidity must be removed so that a
good contact of the connection cable is guaranteed. No aggressive detergent may be used. Please do not
damage socket contacts.
Attention: Cleaning only in powerless state.
2. Plug in the connection cable into the socket in the device back part (consider alignment) and clip the top of the
device upper part into the device back part.
3. Swing down the device upper part until it clicks.
4. The device can only be opened with the supplied special tool! With this, the two catches on the bottom of the
device can be unlocked in succession.
Figure 2.3 - Opening the housing