Mounting the GAT Access 6100 Terminals
www.gantner.com
HB_GAT-ACCESS6100--EN_12
17
2.2 GAT Access 6100 F BIO
2.2.1 Wall Mounting
First, the back part of the GAT FR 055 reader is secured by 3 screws (a) to a flat background (e.g. concrete wall)
according to the following dimensional drawing. When fixing to an uneven background the device back part must
not be distorted, as this will prevent correct connection of the upper part. The recommended mounting height from
the top edge of the device to the floor is 1.3 meters.
.
Figure 2.4 - Dimensions of GAT FR 055 back part and mounting holes (a)
Connection Cables
The connection cables (power supply, network etc.) are run through the cable lead-ins of the GAT FR 055. With
concealed/flush wiring (1) the connection cables are fed from behind via the back box. With surface wiring (2) the
connection cables must lie in the cable duct on the back part of the GAT FR 055.