User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGICĀ®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Electrical Connections
www.gantner.com
HB_GAT-ACCESS6100--EN_12
27
3. ELECTRICAL CONNECTIONS
The connection cables for power supply, data signals and peripheral devices are connected at the screw terminals
on the housing upper part.
Attention: Always disconnect or switch-off power supply before connecting or disconnecting cables at the
GAT Access 6100 in order to avoid injuries for persons and damage to the access terminal!
3.1 Power Supply
The GAT Access 6100 terminals need a power supply between 12 and 24 VDC (see technical data). The power can
be supplied for example by the GAT Power Supply SP014/1 or by the GAT Power Supply SP 031/1 from GANTNER
Electronic GmbH. The power input is protected against reverse-polarity.
Note: If several GAT Access 6100 devices or other devices shall use a single power source, please check the max.
power output of the supply unit. For example, one GAT Power Supply SP014/1 can supply two GAT Access
6100.
Note: The GAT Access 6100 F Enrollment Station is equipped with an already connected power supply unit, which
can be plugged into mains power UAC 230 V.
Figure 3.1 - Power supply of a GAT Access 6100 with a GAT Power Supply SP014/1