User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGICĀ®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Electrical Connections
28
HB_GAT-ACCESS6100--EN_12
www.gantner.com
3.2 Network
The GAT Access 6100 terminals are equipped with an Ethernet interface for communication via a LAN network.
3.2.1 Ethernet Network
The GAT Access 6100 support 10 and 100 Mbit/s communication. It is recommended to connect each GAT Access
6100 directly to a switch or patch panel socket.
Figure 3.2 - Ethernet network example
The Ethernet network cable is connected to the GAT Access 6100 via the TX+, TX-, RX+, RX- screw terminals. No
RJ 45 plug is used. The wires of the Ethernet cable are directly connected to the screw terminals.
Figure 3.3 - Network connection via Ethernet at GAT Access 6100 (with external power supply)
Recommended cables for 100 MBit Ethernet connection are min. CAT 5 (STP).