Electrical Connections
28
HB_GAT-ACCESS6100--EN_12
www.gantner.com
3.2 Network
The GAT Access 6100 terminals are equipped with an Ethernet interface for communication via a LAN network.
3.2.1 Ethernet Network
The GAT Access 6100 support 10 and 100 Mbit/s communication. It is recommended to connect each GAT Access
6100 directly to a switch or patch panel socket.
Figure 3.2 - Ethernet network example
The Ethernet network cable is connected to the GAT Access 6100 via the TX+, TX-, RX+, RX- screw terminals. No
RJ 45 plug is used. The wires of the Ethernet cable are directly connected to the screw terminals.
Figure 3.3 - Network connection via Ethernet at GAT Access 6100 (with external power supply)
Recommended cables for 100 MBit Ethernet connection are min. CAT 5 (STP).