User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGIC®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Start-Up and Configuration
www.gantner.com
HB_GAT-ACCESS6100--EN_12
39
The configuration settings of the GAT Access 6100 are organised into several categories. The directory on the left
(1) lists the different configuration categories. Click on a category and the settings for this category can be viewed
and adjusted in the field to the right (2). A short description of the setting is shown at the bottom of the window (3).
An overview of all the configuration settings is available in Table 4.1.
Note: A more detailed description of all available settings can be found in the GAT Config Manager manual.
4.3.2 Project Configuration
Complete the following steps to configure the GAT Access 6100 via a project in GAT Config Manager.
Click on the “Open Project” icon (1 in Figure 4.17) to find an existing project. Alternatively, click on the “Create
Project” icon (2 in Figure 4.17) to start a new project.
Figure 4.17 – GAT Config Manager - project setup
Once a project is established, click on the “Scan Device” icon (1 in Figure 4.18).
o The software scans the network and displays a list of all connected GANTNER devices.
Select your GAT Access 6100 from the list. Use device details such as the IP and MAC address to identify the
correct device.
o The selected device is highlighted in blue as shown in Figure 4.18.
Click on “OK” (2 in Figure 4.18).
o The selected device is added to the “Devices” list (3 in Figure 4.18).