User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGIC®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Start-Up and Configuration
42
HB_GAT-ACCESS6100--EN_12
www.gantner.com
State low
Fingerprint
Verification Level
Verification level of the finger print sensor. Can be set
between 0 and 10, the recommended value is 5. A
higher value decreases the false acceptances rate; a
lower value decreases the false rejections.
5
Mode Verification
Defines, how the finger print sensor is used:
Deactivated - Finger prints are not used
Data on Card - The finger prints of the users are stored
on their data carriers for verification.
Compatibility - If the host responds to the Card_Ident
Command with the state 0x00, the Verificationprocess
is started (Compatibility Mode)
Deactivated /
Data on Card /
Data on Data-
base /
Compatibility
Number Fingers
Number of different fingers usable for verification
2
Site key
Site key to read/write fingerprint data from data carriers
Display
Contrast
Contrast of the display. Can also be set in the service
menu of the device.
10
Application
General
Time format
Time format used to show time values at the device
Text
0 - 24 / AM / PM
Emergency Mode enabled
Enable the Emergency Mode
Boolean
True
Device Licence
Licence to enable special features of the device, for
example for the GAT Access 6100 F Upgrade (see
"4.4. Configuration of Offline Emergency Mode
for a GAT Access 6100 ").
Hex
4895CA89…
Enrollment Station
Indicates, if the licence activates the Enrollment Station
functionality
Boolean
false
Disable Secure UID
Indicates, if the licence is used to deactivate the
Secure UID
Boolean
false
Thirdparty Validation
Indicates, if the licence is used for third party validation
Boolean
false
Enable GAT Shower
Indicates, if the countdown functionality is activated
Boolean
false
Remaining period mode
Determines the action that will be performed after the
timeout during a remaining period break (see section
“Application” -> “Timeouts”) is exceeded.
Cancel: The countdown process will be cancelled
Continue Relay off: The countdown will proceed, the
relay will be switched off
Continue Relay on: The countdown will proceed, the
relay will be switched on
Cancel
Continue Relay
off
Continue Relay
on
Data handling
Deny if Checkin failed
Access denied if the LockerCheck-In fails
Boolean
false
Check validity date
Checks site number and validity date of data carriers,
when the GAT Access 6100 is in the Emergency Mode
Boolean
false
Locker 1
Read
Indicates, if data must be read from the first locker
segment of the data carriers.
Boolean
true
Position on card
Where the locker data 1 segment is located on data carriers
Integer
1 .. 255
Clear number
Clear the locker number from the data carrier.
Boolean
false
Start date
Mode
Selection of the LockerCheckin Mode for the Start Date
NONE: Value will not be changed
DELAY: Sets the start date to now + start date value
TIME: Sets the start date to today at start date value
FOREVER: Sets the start date to forever valid
Text
NONE / DELAY /
TIME / FOREVER
Hours
Hours of start date
Integer
0 .. 23