User's Manual

Table Of Contents
GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Start-Up and Configuration
www.gantner.com
HB_GAT-ACCESS6100--EN_12
43
Minutes
Minutes of start date
Integer
0 .. 59
End date
Mode
Selection of the LockerCheckin Mode for the End Date
NONE: Value will not be changed
DELAY: Sets the expiry date to now + expiry date value
TIME: Sets the expiry date to today at expiry date value
FOREVER: Sets the expiry date to forever valid
Text
NONE / DELAY /
TIME / FOREVER
Hours
Hours of end date
Integer
0 .. 23
Minutes
Minutes of end date
Integer
0 .. 59
Locker 2
Read
Indicates, if data must be read from the second locker
segment of data carriers.
Boolean
true
Position on card
Defines the segment where locker data 2 is located on
a data carrier
Integer
1 .. 255
Clear number
Clear the locker number from the data carrier.
Boolean
false
Start date
Mode
Selection of the LockerCheckin Mode for the Start Date
NONE: Value will not be changed
DELAY: Sets the start date to now + start date value
TIME: Sets the start date to today at start date value
FOREVER: Sets the start date to valid forever
Text
NONE / DELAY /
TIME / FOREVER
Hours
Hours of start date
Integer
0 .. 23
Minutes
Minutes of start date
Integer
0 .. 59
End date
Mode
Selection of the LockerCheckin Mode for the End Date
NONE: Value will not be changed
DELAY: Sets the expiry date to now + expiry date value
TIME: Sets the expiry date to today at expiry date value
FOREVER: Sets the expiry date to valid forever
Text
NONE / DELAY /
TIME / FOREVER
Hours
Hours of end date
Integer
0 .. 23
Minutes
Minutes of end date
Integer
0 .. 59
Third party (e.g. for GAT Access 6100 F Upgrade, see "4.4. Configuration of Offline Emergency Mode for a GAT
Access 6100 ")
Position on Card Base
Segment number of the third party segment on data
carriers
Integer
1
Block Number
Block number of the third party segment
Integer
0
Mask
The block, that is read from a data carrier, is logical AND
combined with this mask value and then compared with
the Result value
Hex
00000000FFFF
FFFF000…
Result
If the value, which results from logical AND combination of
the read block data from the data carrier and the Mask
value above, matches the Result value, access is granted
Hex
00000000AD33
6000…..
Fingerprint
Position on Card Base
Segment position of the finger print base sector on the
data carriers
Integer
6
Timeouts
Access allowed screen
Duration in milliseconds for the access allowed
process. For a GAT TimeAxx 6150 terminal, this
setting determines the countdown time.
Integer
12000
Access denied screen
Duration in milliseconds for the access denied process.
Integer
3000
Remaining period break
Only for Countdown Mode. Determines, how long the
user can pause the countdown of a GAT TimeAxx
6150 until the whole countdown process is cancelled
(input in milliseconds). The resulting action after
exceeding this timeout is determined by the setting
“Remaining period mode” in the “Application ->
Integer
60000