User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGICĀ®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Troubleshooting and FAQ
72
HB_GAT-ACCESS6100--EN_12
www.gantner.com
Note: See "4.2 System Settings" for more information about the Service mode or Service menu respectively.
8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- Port 8000: For communication
- Port 8208: For configuration (GAT Config Manager)
8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
The GAT Access 6100 operates with bit rates of 10 and 100 Mbit/s. The terminal decides automatically which bit
rate to use or it is also possible to configure the bit rate fix to 10 Mbit/s.
8.5 How can I set the date and time of a GAT Access 6100?
If the date and time of a GAT Access 6100 are no longer correct, it is possible to adjust date and time in different ways:
a) With GAT Config Manager software (see "4.3. Configuration Settings").
b) Directly at the terminal in the Service mode (see 4.2. System Settings")
c) With the FUNLINE protocol command "Set_Date" and "Set_Address".
d) With the software GAT TimeSync, which is part of the GAT SyncManager software.
8.6 How can I find the IP address of a GAT Access 6100 and change it?
There are different possibilities:
a) Read and set the address directly at the GAT Access 6100. The GANTNER technology logo is shown when the
GAT Access 6100 powers on. After a brief pause, the "Settings" screen with information including the IP
address, DHCP ON/OFF, software version, terminal address and reader technology is shown (see "4.2. System
Settings"). The IP address can be changed in the Service menu (see "4.2.1. Service Menu of GAT Access
6100").
b) With the GAT Device Finder software.
c) With GAT Config Manager software.