User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGIC®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Troubleshooting and FAQ
www.gantner.com
HB_GAT-ACCESS6100--EN_12
75
8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
The relay is configured as "External_Locking" and is activated, as soon as the access terminal has read the unique
number UID of a data carrier.
Solution:
Set the relay to "No_Function" or "Turnstile" function.
8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
Offline Commands:
- Set_Address - Repeat_Event - Set_Addr_Extended
- Set_Date - Delete_Events - Set_Protocol_Type
- Ident_Read_Date - Pass_Master - Enable_Baptism
- Test_Connection - TriggerMasterMode - Read_Baptism
- Read_Event - Reset - Clear_Baptism
Online Commands:
- Pass_Master - Card_Ident - Action_Started
8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
In emergency mode a GAT Access 6100 reads a certain segment (LEGIC
®
: configurable, MIFARE
®
: locker
segment, ISO 15693: general segment) of the data carriers. If the site-key is correct (same site-key on data carrier
and in the terminal) access is granted, otherwise the data carrier is rejected and access is denied.
8.17 What is the maximum start-up current consumption of a GAT Access 6100?
V
In
I
max
12 V 7 A
16 V 10 A
20 V 12 A
24 V 15 A
See also chapter “9. Technical Data”.
8.18 What are the factory settings of a GAT Access 6100?
Ethernet:
- TCP Communication Port: 8000
- DHCP enabled: true
- Static IP Address: 192.168.1.37
- Static Subnet Mask: 255.255.255.0
- Static Primary DNS Server: 192.168.1.13
- Static Secondary DNS Server: 192.168.1.11
- Static Default Gateway: 192.168.1.6
- NetBIOS name: GA<PartNo.><SerialNo.>
- 100 Mbit Ethernet enabled: true