User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGIC®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Troubleshooting and FAQ
www.gantner.com
HB_GAT-ACCESS6100--EN_12
77
Locker 2:
- Read: false
- Position on Card: 5
- Clear number: false
Start Date:
- Mode: None
- Hours: 0
- Minutes: 0
End Date:
- Mode: None
- Hours: 0
- Minutes: 0
Fingerprint:
- Position on Card Base: 6
Timeouts:
- Access allowed screen: 3000
- Access denied screen: 3000
MIFARE:
- Site Key: 73E0…
- Subsite: 00
- Enable Subsite: false
8.19 How do I configure a GAT Access 6100 for offline emergency mode?
For the GAT Access 6100, there is the possibility to load an Offline Licence into the terminal. With this licence, the
terminal checks if a specific code string is stored in a defined position on the data carrier and if the data carrier has
access permission.
The Offline Licence can be ordered from GANTNER Electronic GmbH. The serial number and MAC address of the
GAT Access 6100 is required and the licence is valid only for one terminal.
To load the licence into the GAT Access 6100, GAT Config Manager software from GANTNER Electronic GmbH is
used (see chapter "4.4. Configuration of Offline Emergency Mode for a GAT Access 6100 ").
8.20 What is the data carrier certificate?
The GAT Access 6100 checks the data carrier certificate to confirm that it is a GANTNER data carrier. In basic
configuration only GANTNER data carriers are allowed.
It is possible to order a device licence that deactivates the certificate test thereby allowing third party data carriers to
be used.