User's Manual

Table Of Contents
GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Technical Data
www.gantner.com
HB_GAT-ACCESS6100--EN_12
79
9. TECHNICAL DATA
Nominal voltage: 12/24 VDC (SELV - safety extra-low voltage)
Permitted input voltage: 10 to 28 VDC
Aver. power consumption
- GAT Access 6100: 3 W
- GAT Access 6100 F BIO: - Full operation with sensor on: 4.5 W
- Full operation with sensor off: 3.5 W
- GAT Access 6100 F Enrollment Stat.: - Full operation with sensor on: 4.5 W
- Full operation with sensor off: 3.5 W
Data storage: Internal flash memory for configuring and booking memory, data
preservation min. 10 years
Internal clock Crystal-controlled real-time clock, data preservation approx. 12 h (gold-cap)
Reader types
- GAT Access 6100 B: LEGIC
®
Prime
- GAT Access 6100 ISO: ISO 15693
- GAT Access 6100 F: MIFARE
®
- GAT Access 6100 F BIO: MIFARE
®
- GAT Access 6100 F Enrollment Stat.: MIFARE
®
Reader frequency: 13.56 MHz
Control elements: - RFID reader
- 4 function keys
Display elements: - Full graphics monochrome display with white LED background lighting,
resolution 128 x 64 pixels, visible area 50 x 25 mm
- RFID reader (illuminated)
- 4-segment LED display in different colours (green / red / yellow)
- Acoustic signal
Finger print scanner type: Optical sensor, 500 dpi @ 8 bit per pixel, active areas: 13 x 20 mm
Verification time of finger prints: < 0.8 seconds
Identification time: < 1 second
Accepted wrong detection rate: 0.01% (recommended), adjustable
Host interface: Ethernet 10/100 Mbit/s
Signal input: 1 x optocoupler (configurable)
- Input voltage: 0 to 30 VDC, ULow < 2 VDC, UHigh > 6 VDC
- Input current: 4.5 mA
Signal output: 1 x relay (configurable NO/NC)
- Switching voltage: max. 30 VAC/DC
- Continuous current: max. 2 A
- Switching power: max. 60 VA
Connection terminals: 0.5 to 1.5 mm
2
Housing material: - Upper part: Shockproof plastic PMMA
- Lower part: Shockproof plastic PC-ABS
- Stand of Enrollment Station: aluminium
Dimensions: see drawings below