User's Manual
Table Of Contents
- 1. General
- 2. Mounting the GAT Access 6100 Terminals
- 3. Electrical Connections
- 4. Start-up and Configuration
- 5. Operation
- 5.1 Control and Display Elements
- 5.2 General
- 5.3 User Operation at a GAT Access 6100
- 5.4 User Operation at a GAT Access 6100 F BIO
- 5.5 User Operation at a GAT Access 6100 F Enrollment Station
- 5.6 Standard Operation for the GAT TimeAxx 6150 with Countdown Functionality
- 5.7 Online Mode and Emergency Mode
- 5.8 Out of Order Screen
- 5.9 Locker Check-In
- 5.10 General Open Function (Group Entry)
- 5.11 External Release Function
- 6. Communication
- 7. Updating the GAT ACCESS 6100
- 8. Troubleshooting and FAQ
- 8.1 How can I update the firmware of a GAT Access 6100?
- 8.2 How do I configure a GAT Access 6100?
- 8.3 Which TCP/IP ports can be used by a GAT Access 6100?
- 8.4 Which bit rates are used by a GAT Access 6100 for Ethernet and is this configurable?
- 8.5 How can I set the date and time of a GAT Access 6100?
- 8.6 How can I find the IP address of a GAT Access 6100 and change it?
- 8.7 How can I find the MAC address of a GAT Access 6100?
- 8.8 Setting IP address when MAC address is not known and IP address of the terminal is 0.0.0.0
- 8.9 Difference between "Time" and "Delay" in the "Mode" field for Locker Check-In configuration?
- 8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling Edge"?
- 8.11 How can the reader of a GAT Access 6100 B be authorised for LEGIC®?
- 8.12 How can I read or delete the authorisation data of a GAT Access 6100?
- 8.13 How can I configure the display texts of a GAT Access 6100?
- 8.14 The relay of the GAT Access 6100 is activated even if the host has denied access.
- 8.15 Which FUNLINE protocol commands are supported by a GAT Access 6100?
- 8.16 Why does the GAT Access 6100 deny access with my data carrier in Emergency mode?
- 8.17 What is the maximum start-up current consumption of a GAT Access 6100?
- 8.18 What are the factory settings of a GAT Access 6100?
- 8.19 How do I configure a GAT Access 6100 for offline emergency mode?
- 8.20 What is the data carrier certificate?
- 9. Technical Data

GAT Access 6100, GAT Access 6100 F BIO, GAT Access 6100 F Enrollment Station, GAT TimeAxx 6150
Technical Data
www.gantner.com
HB_GAT-ACCESS6100--EN_12
79
9. TECHNICAL DATA
Nominal voltage: 12/24 VDC (SELV - safety extra-low voltage)
Permitted input voltage: 10 to 28 VDC
Aver. power consumption
- GAT Access 6100: 3 W
- GAT Access 6100 F BIO: - Full operation with sensor on: 4.5 W
- Full operation with sensor off: 3.5 W
- GAT Access 6100 F Enrollment Stat.: - Full operation with sensor on: 4.5 W
- Full operation with sensor off: 3.5 W
Data storage: Internal flash memory for configuring and booking memory, data
preservation min. 10 years
Internal clock Crystal-controlled real-time clock, data preservation approx. 12 h (gold-cap)
Reader types
- GAT Access 6100 B: LEGIC
®
Prime
- GAT Access 6100 ISO: ISO 15693
- GAT Access 6100 F: MIFARE
®
- GAT Access 6100 F BIO: MIFARE
®
- GAT Access 6100 F Enrollment Stat.: MIFARE
®
Reader frequency: 13.56 MHz
Control elements: - RFID reader
- 4 function keys
Display elements: - Full graphics monochrome display with white LED background lighting,
resolution 128 x 64 pixels, visible area 50 x 25 mm
- RFID reader (illuminated)
- 4-segment LED display in different colours (green / red / yellow)
- Acoustic signal
Finger print scanner type: Optical sensor, 500 dpi @ 8 bit per pixel, active areas: 13 x 20 mm
Verification time of finger prints: < 0.8 seconds
Identification time: < 1 second
Accepted wrong detection rate: 0.01% (recommended), adjustable
Host interface: Ethernet 10/100 Mbit/s
Signal input: 1 x optocoupler (configurable)
- Input voltage: 0 to 30 VDC, ULow < 2 VDC, UHigh > 6 VDC
- Input current: 4.5 mA
Signal output: 1 x relay (configurable NO/NC)
- Switching voltage: max. 30 VAC/DC
- Continuous current: max. 2 A
- Switching power: max. 60 VA
Connection terminals: 0.5 to 1.5 mm
2
Housing material: - Upper part: Shockproof plastic PMMA
- Lower part: Shockproof plastic PC-ABS
- Stand of Enrollment Station: aluminium
Dimensions: see drawings below