User's Manual

GAT LOCK 6010 F
Installation
www.gantner.com HB_GAT-LOCK6010F--US_16 15
i
The reading range is measured from the button shaft. The drill hole
in the locker door and the button shaft must be centred (see also the
figure Figure 2.11 in the section "2.5.2. Mounting on Metallic Doors"),
otherwise the following specification is not valid.
3.3.1. Non-Metallic Doors
For non-metallic doors the following reading ranges are valid for the different data
carriers:
ISO card like "GAT Chip Card 200 F": approx. 50 mm (2 inch)
GANTNER wristlet "GAT Chip Band 60 F": approx. 30 mm (1.2 inch)
Don’t use metallic number labels (see Figure 2.12).
Those labels will decrease the reading range to the same
reading ranges and restrictions as for metallic doors!
3.3.2. Metallic Doors
The actual reading ranges at metallic doors depend on many factors like the door
thickness, the diameter of the button drill hole, the type of data carrier etc.. The
more the shaft of the lock sticks out of the door the higher the reading range can
be. Reference values for the reading ranges of different locker door thicknesses
and drilling diameters are shown in the diagrams in Figure 2.4.
Test the installation!
In any case a test installation is must be made in order to
test the reading range. The GAT Lock 6010 F must be able
read the used data carriers without any problem!
i
When the GAT Lock 6010 F is mounted in metallic doors, MIFARE
DESFire data carriers cannot be used.