3.5. Installation Instructions
No cabling is necessary, because it is battery operated. The GAT Lock 6010 F is
attached to the wall of the door using four screws.
Recommended screws:
For steel doors: Cheese head screws M5 x 35 mm (1.4 inch)
For wooden or HPL doors: woodscrews ABC Spax 5 x 35 mm (1.4 inch)
For wooden or HPL doors under heavy-duty loads or in public areas: screw-
in muffs or glue-in muffs M5 with pan-head screws M5 x 35 mm (1.4 inch)
The maximum diameter of the screw head may be 9 mm (0.35 inch).
In the case of sheet metal doors, 4 drill holes including M5 thread have to be
made. In the case of wooden and HPL doors, notches have to be made in the 4
hole positions and in the case of harder doors, where the screws cannot be
screwed in easily, the holes have to be pre-drilled.
The drill holes for the screws must not be drilled completely
through the door!
For the button of the GAT Lock 6010 F a hole must be drilled in the locker door.
The recommended diameter for this hole is 23 mm (0.9 inch).
At metallic doors the drill hole diameter has an influence on the reading range for
the data carriers (see "2.3. Reading Ranges") and also the pay attention that the
drill hole and the button is centred (see next pages).
Check that there is no pressure applied to the button shaft
of the GAT Lock 6010 F in assembled state, e.g. by a part
of the locker door or a front label! This could lead to
malfunction of the GAT Lock 6010 F.