4.2.1. Configuration Procedure
1.) Connect the battery compartment to the configuration device (PC, laptop)
using the GAT Lock 6000 Progamming Cable USB.
2.) Install the USB-driver for the programming cable (if not already installed).
3.) a) Press the button as far as it will go using the Service Data Carrier and
keep it pressed for about 1 second until the Service Data Carrier is read.
b) If a GAT Lock 6010 F has the factory default site number of "99999999",
it can be set into service mode without any Service Data Carrier by just
pressing the button by hand (no data carrier needed).
4.) The LED of the lock will begin to flash red and green alternately to signalize
that the GAT Lock 6010 F is now in service mode. If a Service Data Carrier
was used it can be removed again.
5.) Now the GAT Lock 6010 F can be configured using the configuration software
on the PC (e.g. GAT Config Manager). A detailed description of the
configuration can be found in the online help of the software.
6.) After configuration remove the programming cable. The configuration
procedure is completed now.
Figure 3.1 Configuration environment
Pay attention that in case the GAT Lock 6010 F is configured before
installation and the batteries are removed for transport of the lock/locker, the
time and date must be set again after inserting the batteries.