User's Manual

GAT LOCK 6010 F
Operation
34
HB_GAT-LOCK6010F--US_16 www.gantner.com
5.2.2. Free Locker Mode with UID
This operation mode is different from the standard mode "Free Locker Mode" in
the following points:
- All ISO 14443 data carriers are possible.
- The data carrier can have a GANTNER locker segment, but this is not
required for this mode.
- If a locker is locked with a data carrier, the locker number isn´t written onto
the data carrier.
- With each data carrier, any number of lockers can be locked at the same time.
Locking and Unlocking Lockers
1.) Hold the locker door pressed shut with one hand.
2.) Press the button of the GAT Lock 6010 F as far as it will go using the
MIFARE
®
data carrier and keep it pressed for about 1 second.
The information on the data carrier will be read.
3.) a) If the data carrier is valid, the LED will light up green briefly. The action
(locking,unlocking) is carried out.
b) If the data carrier is invalid, the LED will light up red briefly and the GAT
Lock 6010 F is switched off again without an action being carried out.
4.) Release the locker door.