5.2.3. Personal Locker Mode with Programming Card
For operation as a Personal Locker with Programming Card, up to any 32
MIFARE data carriers can be authorised per GAT Lock 6010 F, which may then
open and close this locker as often as required. These 32 data carriers have the
same authorisation (e.g. as family cards).
The authorisations are communicated to the GAT Lock 6010 F by means of a
Programming Data Carrier.
Authorising MIFARE Data Carriers
1.) Hold the locker door pressed shut with one hand.
2.) Press the button of the GAT Lock 6010 F as far as it will go using the
programming data carrier and keep it pressed for about 1 second.
The information on the data carrier will be read.
3.) The GAT Lock 6010 F changes into the Programming mode.
The LED will light up red for about 2 seconds after the Programming Data
Carrier is removed. When the LED will start flashing green and red
alternately the lock is ready for the programming of data carriers.
4.) Now you have 5 seconds to press the button of the lock with the MIFARE
data carrier to be authorised.
5.) a) If the authorisation is successful, the LED will light up green for about 3
seconds. As soon as the data carrier is removed the LED will start flashing
green and red alternately and another data carrier can be programmed
the same way. This process can be repeated until all data carriers are
programmed.
b) If the authorisation is not successful, the LED will light up red briefly 3 times.
Reasons for this could be:
- that 32 MIFARE data carriers are already authorised for this
particular GAT Lock 6010 F
- that the used MIFARE data carrier has already been authorised
- that the MIFARE data carrier could not be read (button not pressed long
or firmly enough).