User's Manual

GAT LOCK 6010 F
Operation
www.gantner.com HB_GAT-LOCK6010F--US_16 41
3.) The LED flashes red briefly for five times.
All Master data carriers have been deleted from the lock. Next the LED
starts flashing green and red alternately and the new Master data carriers
can now be programmed.
4.) Within the next 5 seconds press the button of the GAT Lock 6010 F with a new
Master data carrier.
As soon as the data carrier was recognised correctly the LED will light up
green for 3 seconds. Remove the Master data carrier and the LED will start
flashing green and red alternately. Another Master data carrier can now be
programmed. This can be repeated until all three Master data carriers are
programmed.
5.) Repeat the process until all three Master data carriers are programmed.
The system operator has to guarantee the safe and secure storage of the
master data carriers!
5.3.2. Programming Data Carrier
The programming data carrier is used to program the GAT Lock 6010 F and to
authorise data carriers in the "Personal Locker" mode or to delete the existing
programming and authorisations.
5.3.3. Battery Data Carrier
After a battery replacement the GAT Lock 6010 F is in the Battery Replacement
mode and it has to be set back to the normal operation mode by using a battery
data carrier. The internal action counter is set to zero when the battery data carrier
is used. With a battery change of a GAT Lock 6010 F in "Personal Locker" mode
the authorisations in the lock will not be deleted.
5.3.4. Reset Data Carrier
The reset data carrier is used to delete all the master data carriers stored in a
GAT Lock 6010 F.