User's Manual

GAT LOCK 6010 F
Operation
www.gantner.com HB_GAT-LOCK6010F--US_16 43
5.4. Summary of the LED States
The electronics of the GAT Lock 6010 F is switched-on by pressing the button of
the lock. This will also be signalled with the LED at the button shaft (LED blinks
orange once). After this the following lock states can be signalled with the same
LED.
LED
State
Meaning
Free
Locker
mode
Personal
Locker
mode
Possible actions
green
1x short
flash
Valid MIFARE
®
data carrier has
been read
X
X
Locking/unlocking
possible
green
1 x flash
Battery
replacement
completed
X
X
GAT Lock 6010 F
is again ready for
operation
red
5 x flash
All master data
carriers have been
deleted from the
GAT Lock 6010 F
X
X
New master data
carriers can be
programmed in the
GAT Lock 6010 F.
red
5 x flash
All authorisations
have been
deleted
-
X
red +
green
alternate
flashes
Start-up - service
mode, program-
ming mode
X
X
Ready for
configuration
red
1x brief
flash
Invalid data
carrier or no data
carrier (e.g. when
pressing the
button with only a
finger)
X
X
GAT Lock 6010 F
is switched off
without action,
failed attempt at
authorisation,
replace data
carrier
red
2 x flash
every 5
seconds
Battery almost
empty
X
X
Battery change is
necessary
Table 4.2 - Summary of the LED states