6. SERVICE AND MAINTENANCE
6.1. Changing the Battery
The battery of a GAT Lock 6010 F is dimensioned for a certain number of locking
cycles (see "7. Technical Data"). The number of cycles depends on the used
battery type, the type of locker usage and the environmental conditions. When
the max. locking cycles are reached, the battery capacity will get too low and the
battery must be replaced with a new one. If the battery gets too weak, the locker
can no longer be locked and in this case the LED of the GAT Lock 6010 F will
flash red twice every 5 seconds.
A 6V lithium battery 2CR5 must be used for the GAT Lock 6010 F. The
market offers several batteries of that type. But not every battery of that
type can be used. Only use one of the following batteries:
- Manufacturer: Panasonic, Typ 2CR5
- Manufacturer: Ansmann, Typ 2CR5
- Manufacturer: Sanyo, Typ Y-PC-2CR5-I
- Manufacturer: Duracell, Typ 2CR5
Battery replacement must not take longer than 2 minutes as otherwise the time
and date set in the GAT Lock 6010 F are lost. In this case, the time and date have
to be set again by using the PC (see "3.2 Configuration").
The batteries must be inserted into the GAT Lock 6010 F after the
transportation, i.e. after the lockers are installed on site.
Replacement is only possible using a special battery compartment key (see
Figure 5.1). The battery compartment key has to be kept in a safe place.