User's Manual
Table Of Contents
GAT LOCK 6010 F
Troubleshooting
48
HB_GAT-LOCK6010F--US_16 www.gantner.com
7. TROUBLESHOOTING
7.1. Error Display
If there is a problem with the GAT Lock 6010 F, this is indicated by the LED which
will flash red in this case.
7.2. Error Description
Description: LED flashes red twice (every 5 seconds).
Error: Battery is weak.
Solving the error: Replace battery (see "5.1 Changing the Battery").
Description: GAT Lock 6010 F cannot be locked (Free Locker).
Error: The user is already occupying a locker, the expiry date on the
MIFARE data carrier has passed.
Solving the error: Using a GAT Info 6xxx F, the number of an occupied locker
can be shown by the MIFARE
®
data carrier. If the user has
already occupied a locker, he can only occupy another locker
once he has opened the original locker again using the
MIFARE data carrier or if the data carrier is reinitialised (e.g.
at the reception desk of the facility).
Description: GAT Lock 6010 F cannot be locked (Personal Locker).
Error: The MIFARE data carrier has not been authorised at this
locker.
Solving the error: Authorise the MIFARE data carrier at the locker using a
programming data carrier (see 4.2.3 Personal Locker Mode with
Programming Card).
Description: GAT Lock 6010 F doesn't respond.
Error: Battery is empty.
Solving the error: Change the battery (see "5.1 Changing the Battery").