GAT Vending 6100 BA RFID Payment Terminal for Vending Machines Installation, Configuration, Operation Document Version 1.
GAT Vending 6100 BA Copyright 2017 by GANTNER Electronic GmbH, Schruns (Austria). All rights are reserved. Operating instructions, manuals and software are protected by copyright ©. Copying, duplication, translation, installation in any electronic medium or machine-readable form in whole or in part is prohibited. The sole exception is represented by creation of a back-up copy of software for own use as a safeguard, so far as this is technically possible and recommended by us.
GAT Vending 6100 BA General Warning and Safety Instructions Dear Customer, We congratulate you on selecting a product (appliance or software) from GANTNER Electronic GmbH. Our aim is to ensure our product operates with safety and to your complete satisfaction. To achieve this aim, please take this opportunity to familiarize yourself with the following guidelines: 1.
GAT Vending 6100 BA Contents CONTENTS 1 INTRODUCTION ........................................................................................................................ 7 1.1 1.2 1.3 1.4 1.5 2 DEVICE OVERVIEW .................................................................................................................. 9 2.1 2.2 2.3 3 General Information ................................................................................................................................
GAT Vending 6100 BA Contents 6.4.2 Error: Out of service ............................................................................................................................ 42 6.4.3 Error: No connection to vending machine ........................................................................................... 42 7 TECHNICAL INFORMATION ................................................................................................... 43 7.1 7.2 6 Technical Data .............................
GAT Vending 6100 BA Introduction 1 INTRODUCTION 1.1 About this Manual This manual describes the mechanical installation, electrical connection, and the configuration and commissioning of the GAT Vending 6100 BA with a vending machine. The basic operation of the GAT Vending 6100 BA for the end user is also described. The installation and operation of the vending machine to which the GAT Vending 6100 BA is connected is not included in this manual.
GAT Vending 6100 BA Introduction Instructions, which must be executed by the user, and the results of these instructions are formatted as follows: ► Instruction for user Instruction for user Instruction for user Instruction for user Instruction for user Instruction for user Instruction for user. o Instruction result Instruction result Instruction result Instruction result Instruction result Instruction result Instruction result Instruction result Instruction result. 1.
GAT Vending 6100 BA Device Overview 2 DEVICE OVERVIEW 2.1 Components and Accessories The following components are supplied with the GAT Vending 6100 BA or, where indicated, available to order as an accessory. 1....... GAT Vending 6100 BA 2....... Plastic mounting plate (included with the GAT Vending 6100 BA) 3....... Aluminium mounting plate (available as an accessory – Part No.: 905127) 4....... GAT Vending MDB Kabel (included with the GAT Vending 6100 BA) 5.......
GAT Vending 6100 BA Device Overview 2.2 GAT Vending 6100 BA Functional Description The GAT Vending BA 6100 BA is a read / write terminal for cashless payment at vending machines. The identification of facility guests by the GAT Vending 6100 BA is done using contactless RFID data carriers (Radio Frequency Identification).
GAT Vending 6100 BA Installation 3 INSTALLATION 3.1 General Information There are two methods for installing the GAT Vending 6100 BA. - For vending machines with standard EVA cutouts, the aluminum mounting plate can be ordered as an accessory (Part No. 905127) and used to mount the terminal. - For vending machines without standard EVA cutouts, corresponding holes must be drilled into the front side of the vending machine. The aluminium mounting plate is not absolutely mandatory for installation. 3.
GAT Vending 6100 BA Installation To install the GAT Vending 6100 BA in vending machines with standard EVA cutouts, proceed with the following instructions and accompanying diagrams. ► Position the aluminium mounting plate next to the cutout on the inside of the vending machine in the correct orientation as shown in Figure 3.2. ► Attach the aluminium mounting plate to the vending machine using four bolts, washers and nuts (not included with the aluminium mounting plate). 1 .......
GAT Vending 6100 BA Installation ► Position the plastic mounting plate next to the previously attached aluminum mounting plate on the outside of the vending machine in the correct orientation as shown in Figure 3.3. ► Attach the plastic mounting plate to the aluminium mounting plate on the front of the vending machine using three M3 x 8 mm bolts (included with the plastic mounting plate). The bolts are attached directly to the threaded holes in the aluminium mounting plate (2 in Figure 3.1).
GAT Vending 6100 BA Installation 3.3 Installation in Vending Machines without Standard Cutouts ► Position the plastic mounting plate on the outside of the vending machine in the correct orientation as shown in Figure 3.4. ► Mark the positions of the three mounting holes (2 in Figure 3.4). ► Drill the three mounting holes in the outer wall of the vending machine.
GAT Vending 6100 BA Installation 3.4 Attaching the GAT Vending 6100 BA to the Mounting Plate After the connection cabling is connected to the GAT Vending 6100 BA (see "4. Electrical Connections"), the GAT Vending 6100 BA is attached to the mounting plate as follows. ► Align the GAT Vending 6100 BA onto the mounting plate so that both holding screws (3) go through the openings in the mounting plate and both hooks on the mounting plate also align with the corresponding openings in the GAT Vending 6100 BA.
GAT Vending 6100 BA Installation 3.5 Detaching the GAT Vending 6100 BA from the Mounting Plate To detach the GAT Vending 6100 BA from the mounting plate, the supplied GAT Reader WK special tool is required. The procedure for detachment is as follows. ► Insert the "GAT Reader WK" special tool (2) with its long side from underneath into the opening (1) until the hook is released. Keep the GAT Reader WK in this position. ► Slide the GAT Vending 6100 BA upwards.
GAT Vending 6100 BA Electrical Connections 4 ELECTRICAL CONNECTIONS Safety Warning for the GAT Vending 6100 BA Due to its SELV (Safety Extra Low Voltage Supply) design, the GAT Vending 6100 BA provides extra protection against electrical shock. However, be aware that vending machines operate at higher voltages so it is essential to always turn off the power supply of the vending machine before connecting the GAT Vending 6100 BA. Never open the GAT Vending 6100 BA housing when voltage is applied.
GAT Vending 6100 BA Electrical Connections 4.2 Ethernet Connection The GAT Vending 6100 BA has one Ethernet connection, which is available via the RJ45 socket on the rear part of housing. A direct Ethernet connection to the GAT Vending 6100 BA is only required for configuration. To connect via Ethernet, one network cable with a minimum specification of CAT 5 (STP) is required. The GAT Vending 6100 BA supports data rates of 10 to 100 Mbit/s.
GAT Vending 6100 BA Startup and Configuration 5 STARTUP AND CONFIGURATION Ensure the installation process and electrical connections have been carried out as described in the previous chapters. The GAT Vending 6100 BA starts automatically when power is applied to the device. For the configuration of the GAT Vending 6100 BA, the difference between the system settings and the configuration settings must be clarified.
GAT Vending 6100 BA Startup and Configuration Figure 5.2 – System settings of the GAT Vending 6100 BA The system settings can be accessed and configured via the service menu (see "5.2.1. Service Menu "). If the user does not actively open the service menu at the terminal, the GAT Vending 6100 BA continues to startup before entering into idle mode. The main screen is displayed and the RFID reading field flashes blue. Figure 5.3 – Main screen (example) 20 HB_GAT-VENDING6100BA--EN_121 www.gantner.
GAT Vending 6100 BA Startup and Configuration 5.2 System Settings The system settings of the GAT Vending 6100 BA can be configured directly on-site via the service menu of the terminal. Alternatively, some of the settings can be defined via the network using GAT Config Manager software. 5.2.1 Service Menu The service menu can be accessed during startup of the GAT Vending 6100 BA when the device settings (see Figure 5.2) are shown on the display.
GAT Vending 6100 BA Startup and Configuration Navigation within the service menu is done by pressing the corresponding keys. The current function for each key is shown at the bottom of the display and this can change depending on the menu. However, as a general guide: ► Keys 1 and 2 control movement up and down respectively. ► Key 3 is the "ESC" key and used to exit the menu. ► Key 4 is the "OK" key and used for confirmation.
GAT Vending 6100 BA Startup and Configuration - MAC Address: The hardware MAC address of the GAT Vending 6100 BA. This cannot be changed. 5.2.3 Reader Settings Different settings for the RFID reader of the GAT Vending 6100 BA are available in this menu. Figure 5.8 - Reader settings menu The RFID reader type of the GAT Vending 6100 BA is shown on the first line (here "Legic Adv"). The following functions are available in this menu: Read UID No.
GAT Vending 6100 BA Startup and Configuration 5.2.5 Display Settings Different settings for the display of the GAT Vending 6100 BA are available in this menu. Contrast The contrast between black and white on the display of the GAT Vending 6100 BA can be adjusted. ► Select "Display” and then the “Contrast” menu item. Figure 5.10 - Setting the contrast of the GAT Vending 6100 BA ► Change to the contrast value using key 3 "". ► Change the value using keys 1 "" and 2 "".
GAT Vending 6100 BA Startup and Configuration 5.3 Configuration Settings The configuration settings are the device functions that determine how the GAT Vending 6100 BA interacts with the user. These settings can be viewed and modified using "GAT Config Manager" PC software. This section provides an overview on how to define the configuration settings with GAT Config Manager. A user guide is available when you install GAT Config Manager.
GAT Vending 6100 BA Startup and Configuration ► Select the communication type. Choose “TCPIP” for the GAT Vending 6100 BA. ► Click on “Next”. Figure 5.13 - Open device for direct configuration (Wizard step 1) ► Enter the IP address and port number of the GAT Vending 6100 BA. ► Click on “Next”. Figure 5.14 - Open device for direct configuration over TCP/IP (Wizard step 2) 26 HB_GAT-VENDING6100BA--EN_121 www.gantner.
GAT Vending 6100 BA Startup and Configuration Figure 5.15 - Ready to start configuration (Wizard step 3) ► Press "Start configuration". o GAT Config Manager connects to the GAT Vending 6100 BA and after a short pause, uploads and displays the current configuration of the device. Figure 5.16 – Configuration window of the GAT Vending 6100 BA www.gantner.
GAT Vending 6100 BA Startup and Configuration The configuration settings of the GAT Vending 6100 BA are organized into several categories. The directory on the left (1) lists the different configuration categories. ► Click on a category and the settings for this category can be viewed and adjusted in the field to the right (2). o A short description of the setting is shown at the bottom of the window (3). An overview of all the GAT Vending 6100 BA configuration settings is available in section “5.3.
GAT Vending 6100 BA Startup and Configuration Figure 5.18 – Network scan to add a device The main project window displays all the information that has been entered into GAT Config Manager. Click on the GAT Vending 6100 BA in the “Devices” list and information about the selected device is shown to the right of the project tree. Here you can view the predefined device and network settings. Figure 5.19 – Project window www.gantner.
GAT Vending 6100 BA Startup and Configuration To configure the display texts of the GAT Vending 6100 BA, click on the "Display Texts" tab. Here you can edit each individual message that is displayed on the selected terminal (see "5.3.3. Display Texts"). Click on the "(2) Configure" button to view and adjust the configuration settings of the GAT Vending 6100 BA. The existing configuration is uploaded from the terminal and displayed in the configuration window. See Figure 5.
GAT Vending 6100 BA Startup and Configuration In the “Key” column of Figure 5.20, the type of message is identified and in the “Value” column, the text can be entered. Each separate line of text is shown on a separate line of the display. The maximum length of 1 text line is 21 characters. If a line of text does not fit on the display of the GAT Vending 6100 BA using the standard font size, the GAT Vending 6100 BA automatically uses a smaller font size to display the entire text line.
GAT Vending 6100 BA Startup and Configuration Vend_Failed Always_Idle Bookings_Lock offl_cashback offl_refund_OK Is shown when the vending machine fails to deliver the user’s selected product. This message is shown while the GAT Vending 6100 BA waits for the user to select a product. Vending failed Choose product For online + emergency mode. Shown when the memory capacity of the GAT Vending 6100 BA is reached. Booking For offline mode.
GAT Vending 6100 BA Startup and Configuration 5.3.4 List of Configuration Settings The following table lists all the configuration settings available for the GAT Vending 6100 BA in GAT Config Manager. A brief description and the format (where applicable) for each setting are shown in the table. Make sure to enter data in the indicated format for settings such as time definitions, etc.
GAT Vending 6100 BA Startup and Configuration User Read Cash 1 Read Cash 2 Read Access Read Third party Read Timeouts Ident timeout Product draw timeout Idle timeout Feedback screen Cashless Device Default currency code Country code Scale factor Decimal places Force single vend Use VMC display Online request MDB address Verify age Check card available Auto reset timeout Bus Timeout Factor VMC Status VMC connection VMC feature level VMC feature bits VMC manufacturer VMC serial number VMC model number VM
GAT Vending 6100 BA Startup and Configuration Emergency Mode Funds Simulated account balance (in cents) for every data carrier in emergency mode Select the price setting: “Default Price”, “Price List”, “Discount Group”, “Discount”, “Surcharge” Define a percentage price discount / surcharge Define the user group Define the pricelist / discount group Option to allow revaluing in emergency mode Option to simulate a valid card with emergency mode settings.
GAT Vending 6100 BA Startup and Configuration Mifare Classic Sector number Site key Read key Mifare DESFire Key set Read key number Application ID Encryption mode FileNum FileCommMode FileType ISO Block number LEGIC Search string Search string length Read only parameter Production Production Data Hardware Version Serial Number Software Version Sector number of the MIFARE Classic third party segment Site key of the MIFARE Classic third party segment Read key of the MIFARE Classic third party segment Integ
GAT Vending 6100 BA Operation 6 OPERATION Explained in this chapter are the different operating modes of the GAT Vending 6100 BA and the process required to purchase a product from a vending machine. As there are many different types of vending machine available, a range of operating conditions are possible. Therefore, a standard operation is described here and please also refer to the user manual of the vending machine for more detailed information. 6.
GAT Vending 6100 BA Operation 6.1.3 Offline Mode In offline mode, the GAT Vending 6100 BA operates autonomously and does not connect to a server/host for data evaluation and control. All information required to complete a vending transaction, such as the user’s account balance, is stored on the data carrier. Offline mode is only valid for LEGIC data carriers with a GANTNER cash segment. In offline mode, the terminal reads the data carrier and displays the user’s account balance.
GAT Vending 6100 BA Operation 6.2 Control and Display Elements For user guidance, the GAT Vending 6100 BA is equipped with various control and display elements. This includes an LCD display, LEDs integrated into the RFID reading field and status bar, and a tone generator for acoustic signaling. Four function keys are also provided for menu navigation and product selection. 1....... LED status bar 2 ...... Display 3 ...... Reading field LED 4 ...... Function keys Figure 6.
GAT Vending 6100 BA Operation 6.2.2 LED Status Bar To indicate the current state of operation or to warn of an error, the LED status bar is designed to emit different colors (red or green) and styles (solid or blinking). The following table defines the LED status bar signaling. Signal Definition Solid red - No connection to the vending machine. - No connection to server/host. Terminal in out of operation mode.
GAT Vending 6100 BA Operation 6.3 Purchasing a Product The standard procedure for purchasing and dispensing a product at a vending machine controlled by the GAT Vending 6100 BA is as follows: ► The GAT Vending 6100 BA displays a message inviting the user to read their data carrier. The LED status bar illuminates red and the RFID reader illuminates blue. ► Hold your data carrier next to the RFID reader. o The GAT Vending 6100 BA displays your current account balance.
GAT Vending 6100 BA Operation 6.4 Troubleshooting If an error or a fault occurs with the GAT Vending 6100 BA, the terminal indicates this state via its display, beeper and status LEDs. The following information assists to identify errors. The text shown on the display can be modified. The texts shown below are the default texts as described in section” 5.3.3 Display Texts”. 6.4.
GAT Vending 6100 BA Technical Data 7 TECHNICAL INFORMATION 7.1 Technical Data Permitted input voltage UDC: 20 to 35 V (MDB) Max. current consumption: 200 mA Max. transmission power: 200 mW Protection: Surface Mount Fuse AVX F0805B2R00FSTR (2A / 63V, Fast Blow type), ensures that the GAT Vending 6100 BA operates within the LPS limits. Frequency of reading field: 13.
GAT Vending 6100 BA Technical Data 7.2 Dimensions 1 ....... LED status bar 2 ....... Display (LCD) 3 ....... Function keys 4 ....... Illuminated, round scan field 5 ....... Device back part 6 ....... Device front part 7 ....... Plastic mounting plate 8 ....... Aluminium mounting plate (accessory) 44 HB_GAT-VENDING6100BA--EN_121 www.gantner.
GAT Vending 6100 BA Technical Data This product is herewith confirmed to comply with the requirements set out in the Council Directives on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility Directive 2004/108/EG.
GAT Vending 6100 BA Technical Data 46 HB_GAT-VENDING6100BA--EN_121 www.gantner.
GANTNER Electronic GmbH GANTNER Electronic GmbH Deutschland GANTNER Electronics Pty Ltd Australia Montafonerstraße 8 Industriestraße 40F 3/105a Vanessa Street, Kingsgrove 6780 Schruns 44894 Bochum NSW 2208 Sydney Austria Germany Australia T: +43 (0)5556 73784-0 T: +49 (0)234 58896-0 T: +61 (0)2 9011 8114 F: +43 (0)5556 73784-8000 F: +49 (0)234 58896-11 F: +61 (0)2 8209 1708 info@gantner.com info-de@gantner.com info-aus@gantner.com GANTNER Electronics Ltd.