GAT ECO.Side Lock 7000 BA / NW BA Battery-Powered Multi-Technology Electronic Lock Installation, Commissioning, Operation Document Version 1.4 www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA © Copyright 2018 by GANTNER Electronic GmbH, Schruns (Austria). Operating instructions, manuals and software are protected by copyright. All rights are reserved. Copying, duplication, translation, installation in any electronic medium or machine-readable form in whole or in part is prohibited. The sole exception is represented by creation of a back-up copy of software for own use as a safeguard, so far as this is technically possible and recommended by us.
GAT ECO.Side Lock 7000 BA / NW BA Important Information Dear Customer, Our aim is to ensure that our product operates with safety and to your complete satisfaction. To achieve this aim, please take this opportunity to familiarize yourself with the following guidelines. - Pay attention to the safety messages in this manual. The messages are indicated by the signal words "DANGER", "WARNING", or "CAUTION", and inform you about hazardous situations and how to avoid them.
GAT ECO.Side Lock 7000 BA / NW BA 2. Property Damage Messages Property damage messages are used to describe potentially hazardous situations that may lead to property damage. These messages have the same layout as safety messages but use the signal word "NOTICE" instead of “CAUTION”. Format of property damage messages that apply to an entire section: Risk of damage to the device and connected devices Risk of malfunction - Read the following instructions carefully before installing the device.
GAT ECO.Side Lock 7000 BA / NW BA Important Safety Information − The installation, commissioning, and servicing of our products must be performed only by suitably trained personnel. In particular, electrical connections must only be made by correspondingly qualified specialists. Always observe the relevant installation regulations in accordance with the national Electrical Engineers Association. ➔ Unqualified personnel may potentially perform actions that result in injury due to electrical shock.
GAT ECO.Side Lock 7000 BA / NW BA The GAT ECO.Side Lock 7000 BA / NW BA was developed and fabricated under the quality management standard ISO 9001 and GANTNER Electronic GmbH is also certified according to standard ISO 14001. This product is in conformity with the following EC directives, including all applicable amendments: - 2014/53/EU (Radio Equipment Directive) The complete text of the CE Declaration of Conformity is available on the following internet link: http://www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA Table of Contents TABLE OF CONTENTS 1 INTRODUCTION .............................................................................................................. 9 1.1 1.2 1.3 1.4 1.5 2 GENERAL INFORMATION ........................................................................................... 11 2.1 2.2 2.3 2.4 2.5 3 About this Manual ...................................................................................................................................
GAT ECO.Side Lock 7000 BA / NW BA Table of Contents 5 CONFIGURATION......................................................................................................... 39 5.1 5.2 5.3 5.4 5.5 5.6 6 OPERATION ................................................................................................................. 49 6.1 6.2 6.3 6.4 6.5 6.6 6.7 7 Target Group ....................................................................................................................................
GAT ECO.Side Lock 7000 BA / NW BA Introduction 1 INTRODUCTION 1.1 About this Manual This manual provides information on the functionality of the GAT ECO.Side Lock 7000 BA and GAT ECO.Side Lock 7000 NW BA and includes an overview of how to configure the locks using GANTNER’s configuration software, “GAT Config Manager”. There is a separate manual available for GAT Config Manager that explains all functions associated with the software in greater detail. The name “GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Introduction 1.4 Target Group This manual contains information relevant for the different stages in the operating life of the GAT ECO.Side Lock 7000 BA / NW BA. Information about the installation, commissioning, and service/maintenance of the GAT ECO.Side Lock 7000 BA / NW BA is separated into corresponding chapters. When a chapter is intended for a specific audience, this is clarified at the beginning of the chapter.
GAT ECO.Side Lock 7000 BA / NW BA General Information 2 GENERAL INFORMATION 2.1 Intended Use The GAT ECO.Side Lock 7000 BA is intended for the electronic locking of wardrobe lockers in facilities such as fitness clubs, baths, golf resorts, hotels, and other individual company applications. The GAT ECO.Side Lock 7000 BA is locked / unlocked using contactless RFID (Radio Frequency Identification) data carriers. 2.2 Functional Description The GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA General Information 2.3 Terminology Several key terms that are used often in this manual are defined below. Computer / PC These terms refer to all desktop and laptop computers running a Microsoft Windows® operating system. Data Carrier A data carrier is a form of identification media that is used by staff and visitors in a facility for identification. Data carriers are available in a variety of different forms such as plastic wristbands and chip cards.
GAT ECO.Side Lock 7000 BA / NW BA General Information 2.4 RFID Technology Identification of users by GANTNER devices within a facility is achieved via RFID (radio-frequency identification) technology using a frequency of 13.56 MHz. There are various RFID technologies available with different letters added to the GANTNER model name to notify of the technology the device supports: - "B": LEGIC - "F": MIFARE® - "ISO": ISO 15693 - “ICLS”: HID iCLASS® The GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA General Information 2.5 System Components The GAT ECO.Side Lock 7000 BA system consists of the following system parts. 1. GAT ECO.Side Lock 7000 BA / NW BA For lockers with non-metallic doors For lockers with glass doors 4. GAT NET.Lock BoltSet 7300 2. GAT NET.Lock BoltSet 7100 For lockers with metallic doors 3. GAT NET.Lock BoltSet 7200 7. Battery Tadiran SL-860/S (EU) Tadiran TL-4903/S (US) 5. GAT NET.Lock Tool 7000 8. GAT ECO.Basic Set B BA 6. GAT NET.
GAT ECO.Side Lock 7000 BA / NW BA General Information 1. GAT ECO.Side Lock 7000 BA (Part No. 583125) Battery-powered locker lock with multi-technology RFID reader. Without batteries, without bolt set, and without door label. GAT ECO.Side Lock 7000 NW BA (Part No. 800925) Battery-powered locker lock with multi-technology RFID reader and wireless interface. Without batteries, without bolt set, and without door label. 2. GAT NET.Lock BoltSet 7100 (Part No. 369535) Bolt set with door shackle and booster.
GAT ECO.Side Lock 7000 BA / NW BA General Information 16 HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14 www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3 INSTALLATION This chapter describes the process and what must be considered to install the GAT ECO.Side Lock 7000 BA and NW BA into lockers with metallic, non-metallic, and glass doors. Since the mounting process is identical for both lock variants, the general term GAT ECO.Side Lock 7000 BA is used. Risk of damage or failure to the GAT ECO.Side Lock 7000 BA - Read the information in this section carefully before installing the GAT ECO.Side Lock 7000 BA.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3.3 Test Installation As the GAT ECO.Side Lock 7000 BA is suitable for a wide range of installation applications, always perform a test installation including functional testing of the GAT ECO.Side Lock 7000 BA in a sample locker from the facility before starting with the mass production of lockers. The following important points must be met. Ensure that: - The door shackle slides centrally into the opening of the GAT ECO.Side Lock 7000 BA.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3.6 Door Status Contact The GAT ECO.Side Lock 7000 BA has a feedback contact (2 in Figure 3.3) that is activated by the door contact (1 in Figure 3.3) when the locker door is closed. It is important that this contact remains clean and undamaged to ensure the correct functionality of the GAT ECO.Side Lock 7000 BA. Figure 3.3 – Door status contact 3.7 Transportation Guidelines The electronics of the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3.9 Measurement Diagrams for Installation Door Width The minimum door width allowed (measured from the door shackle to the hinge) is 230 mm (9.05´´). If the door is narrower, the door shackle will hit the locker when the door is being closed. Figure 3.4 - Minimum door width Dimensions of the GAT ECO.Side Lock 7000 BA and GAT NET.Lock Bolt Sets Figure 3.5 - Dimensions of the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Installation Figure 3.6 - Dimensions of the GAT NET.Lock BoltSet 7100 (dimensions in mm – inches in brackets) Figure 3.7 - Dimensions of the GAT NET.Lock BoltSet 7200 (dimensions in mm – inches in brackets) Figure 3.8 - Dimensions of the GAT NET.Lock BoltSet 7300 (dimensions in mm – inches in brackets) 1. GAT ECO.Side Lock 7000 BA 2. Door shackle 3. Door contact www.gantner.com 4. Status LED 5. Label carrier (front cover on door outer side) 6.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3.10 Installation in Lockers with Non-Metallic Doors (Except Glass) For lockers with non-metallic doors, the GAT ECO.Side Lock 7000 BA is mounted on the left or right inner locker wall depending on whether it is a right or left-hinged locker door. The GAT NET.Lock Bolt Set 7100 is mounted on the inside of the locker door. A drill hole is required in the locker door for the status LED. See the diagram below and the following installation instructions.
GAT ECO.Side Lock 7000 BA / NW BA Installation Installation Requirements for the GAT ECO.Side Lock 7000 BA and Non-Metallic Doors During installation, please pay particular attention to the following points: - - When the door is pressed shut, ensure there is no gap between the bolt set (2) and the front of the GAT ECO.Side Lock 7000 BA. Ideally the bolt set should touch the front of the lock (see Figure 3.9). The locker door, the bolt set, and the front side of the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Installation Installation Instructions for the GAT ECO.Side Lock 7000 BA and Non-Metallic Doors Complete the following steps to install the GAT ECO.Side Lock 7000 BA into lockers with non-metallic doors. ► Drill 3 holes (3 in Figure 3.9) for the GAT ECO.Side Lock 7000 BA into the locker wall inner side according to the information in "3.10.1 Installation Requirements for the GAT ECO.Side Lock 7000 BA and Non-Metallic Doors” and the measurements in Figure 3.9.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3.11 Installation in Lockers with Metallic Doors For lockers with metallic doors, the GAT ECO.Side Lock 7000 BA is mounted on the left or right inner locker wall depending on whether it is a right or left-hinged locker door. Two cutouts must be made in the locker door - one in the inner door sheet and one in the outer door sheet. The two parts of the GAT NET.Lock Bolt Set 7200 are then mounted into the locker door.
GAT ECO.Side Lock 7000 BA / NW BA Installation Cutouts in the Locker Door The following cutouts must be made on the inner and outer walls of the locker door in order to mount the GAT NET.Lock BoltSet 7200 and label carrier. The measurements for the cutouts are as follows. Figure 3.12 - Cutouts for metallic locker doors (dimensions in mm – inches shown in brackets) 26 HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14 www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA Installation Installation Requirements for the GAT ECO.Side Lock 7000 BA and Metallic Doors During installation, please pay attention to the following points: - - The thickness of the locker door must be between 18 and 26 mm (0.71´´ and 1.02´´). See Figure 3.11. When the door is pressed shut, ensure there is no gap between the bolt set (2) and the front of the GAT ECO.Side Lock 7000 BA. Ideally the bolt set should touch the front of the lock (see measurement in Figure 3.
GAT ECO.Side Lock 7000 BA / NW BA Installation Installation Instructions for the GAT ECO.Side Lock 7000 BA and Metallic Doors Complete the following steps to install the GAT ECO.Side Lock 7000 BA into lockers with metallic doors. ► Drill 3 holes (3 in Figure 3.11) for the GAT ECO.Side Lock 7000 into the locker wall inner side according to the information in section "3.11.2 Installation Requirements for the GAT ECO.Side Lock 7000 BA and Metallic Doors" and the measurements in Figure 3.11.
GAT ECO.Side Lock 7000 BA / NW BA Installation 3.12 Installation in Lockers with Glass Doors For lockers with glass doors, the GAT ECO.Side Lock 7000 BA is mounted on the left or right inner locker wall depending on whether it is a right or left-hinged locker door. The GAT NET.Lock Bolt Set 7300 (with metal support attached) are glued to the inner side of the locker door. Furthermore, a recess in the printing on the locker door or door label may be necessary for the status LED.
GAT ECO.Side Lock 7000 BA / NW BA Installation Installation Requirements for the GAT ECO.Side Lock 7000 BA and Glass Doors Please pay attention to the following points during installation: - When the door is pressed shut, ensure there is no gap between the bolt set (2) and the front of the GAT ECO.Side Lock 7000 BA. Ideally the bolt set should touch the front of the lock (see Figure 3.15). The locker door, the bolt set, and the front side of the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Installation Installation Instructions for the GAT ECO.Side Lock 7000 BA and Glass Doors Complete the following steps to install the GAT ECO.Side Lock 7000 BA into lockers with glass doors. ► Drill 3 holes (3 in Figure 3.15) for the GAT ECO.Side Lock 7000 BA into the locker wall inner side according to the information in section “3.11.2 Installation Requirements for the GAT ECO.Side Lock 7000 BA and Metallic Doors” and the measurements in Figure 3.15.
GAT ECO.Side Lock 7000 BA / NW BA Installation 32 HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14 www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA Commissioning 4 COMMISSIONING 4.1 Target Group This chapter provides information for technicians responsible for putting the GAT ECO.Side Lock 7000 BA and NW BA into operation. A base knowledge of electronics is assumed. Previous knowledge of the GAT ECO.Side Lock 7000 BA / NW BA is not required. Since the comissioning process is identical for both lock variants, the general term GAT ECO.Side Lock 7000 BA is used. 4.2 Power Supply Battery Information The GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Commissioning Figure 4.1 - GAT ECO.Side Lock 7000 BA battery compartment ► Ensure that the battery polarity is the same as shown in Figure 4.1. ► Press the battery down into the compartment until it locks into place. ► Reinstall the battery cover over the battery compartment and push down until the battery cover is level with the surrounding GAT ECO.Side Lock 7000 BA housing. o When installing the battery in the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Commissioning Do not operate the GAT ECO.Side Lock 7000 BA while replacing the batteries. Following battery replacement, the GAT ECO.Side Lock 7000 BA must be returned to its normal operating mode using the Battery data carrier (see section “6.5.3. BATTERY Data Carrier”). In addition, the time and date must be set again using a PC and GAT Config Manager (see section “5 CONFIGURATION”). ► Unscrew the 3 screws that hold the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Commissioning ► Plug the Micro-B connector of the USB cable into the USB port on the GAT ECO.Side Lock 7000 BA. o After connecting the GAT ECO.Side Lock 7000 BA to the PC/laptop for the first time, the lock drivers are installed, and the lock is automatically recognized. If a driver is requested, they are available on the “Leisure Software” USB stick, which is included in the GAT ECO.Basic Set B BA. ► Hold the SERVICE data carrier next to the RFID reading field.
GAT ECO.Side Lock 7000 BA / NW BA Commissioning 4.4 Automatic Antenna Adjustment The antenna of the GAT ECO.Side Lock 7000 BA must be calibrated to ensure the optimal reading range for the RFID data carriers. To complete this calibration, the lock is equipped with an automatic antenna adjustment function that is activated using the SERVICE data carrier or via GAT Config Manager. Antenna Adjustment using the Service Data Carrier The SERVICE data carrier is included in the GAT ECO.Basic Set B BA (see “6.
GAT ECO.Side Lock 7000 BA / NW BA Commissioning 38 HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14 www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA Configuration 5 CONFIGURATION 5.1 General Information The GAT ECO.Side Lock 7000 BA is configured using a PC/laptop and GAT Config Manager software. The configuration file must only be uploaded to the GAT ECO.Side Lock 7000 BA once. The configuration file for the first lock in the system is saved in GAT Config Manager and can then be uploaded to each lock that requires the same configuration.
GAT ECO.Side Lock 7000 BA / NW BA Configuration Complete the following steps to setup for configuration in GAT Config Manager. ► After installing the software, open GAT Configuration Manager via "Start" -> "All Programs" -> "GANTNER Electronic GmbH" -> "GAT Config Manager" -> "GAT Config Manager". ► Click on the “Open Project” icon (1 in Figure 5.1) to find an existing project. Alternatively, click on the “Create Project” icon (2 in Figure 5.1) to start a new project.
GAT ECO.Side Lock 7000 BA / NW BA Configuration Figure 5.3 – GAT Config Manager – Adding a GAT ECO.Side Lock 7000 BA 5.3 View and Edit the GAT ECO.Side Lock 7000 BA Configuration Settings Once the connected GAT ECO.Side Lock 7000 BA has been added to the “Devices” directory, you can now view and adjust the configuration settings of the lock. Complete the following steps to view the configuration settings. ► Select the GAT ECO.Side Lock 7000 BA from the “Devices” directory (1 in Figure 5.
GAT ECO.Side Lock 7000 BA / NW BA Configuration ► Click on the “(2) Configure” button (2 in Figure 5.4). o The GAT Configurator window opens (Figure 5.5). Figure 5.5 – GAT Configurator window 5.4 Upload Configuration Settings to the GAT ECO.Side Lock 7000 BA When you are finished configuring the GAT ECO.Side Lock 7000 BA settings in GAT Config Manager, it is important to finalize the configuration by uploading the file to the lock. Complete the following steps to finalize the configuration.
GAT ECO.Side Lock 7000 BA / NW BA Configuration 5.5 Updating the GAT ECO.Side Lock 7000 BA Firmware GANTNER periodically releases firmware updates for the GAT ECO.Side Lock 7000 BA. In order to take advantage of the latest features, it is recommended to update the GAT ECO.Side Lock 7000 BA to the latest firmware during configuration or at regular intervals. ► Right-click onto the GAT ECO.Side Lock 7000 in the “Devices” tree and select “Update Firmware”. Figure 5.6 – Updating the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Configuration 5.6 Configuration Settings of the GAT ECO.Side Lock 7000 BA The main configuration settings of the GAT ECO.Side Lock 7000 BA that can be adjusted in GAT Config Manager are explained in this section. A list and brief explanation of every configuration setting available for the GAT ECO.Side Lock 7000 BA can be found in section “5.6.9 Configuration Settings Table”. Operating Mode The GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Configuration Auto-Unlock The auto-unlock function automatically unlocks the GAT ECO.Side Lock 7000 BA at a defined point in time. The time must be set correctly once via software. NOTE! When this function is activated, the lock will always unlock at the defined point of time regardless of the operating mode (see “6.3 Operating Modes”).
GAT ECO.Side Lock 7000 BA / NW BA Configuration Configuration Settings Table The following table lists all the configuration information available for the GAT ECO.Side Lock 7000 BA in GAT Config Manager.
GAT ECO.Side Lock 7000 BA / NW BA Configuration Options Description Format Default When set to “True”, LEGIC data carriers can be read by the lock. This setting is not configurable When set to “True”, ISO 15693 data carriers can be read by the lock. When set to “True”, ISO 14443 (MIFARE) data carriers can be read by the lock. Boolean True Boolean False Boolean False Hex 9999 LEGIC prime Site key of the device. All data carriers must have the same site key to be used with the device.
GAT ECO.Side Lock 7000 BA / NW BA Configuration 48 HB_GAT-GAT-ECOSide-Lock7000-BA--EN_14 www.gantner.
GAT ECO.Side Lock 7000 BA / NW BA Operation 6 OPERATION 6.1 General The GAT ECO.Side Lock 7000 BA can operate in "free locker" mode or "personal locker" mode. In free locker mode, the locker user may select any unoccupied locker they want to use. In personal locker mode, locker users are assigned a specific locker to which only they have access. When free lockers and personal lockers are used together in one system, it is recommended that the locker numbers are unique for both functions.
GAT ECO.Side Lock 7000 BA / NW BA Operation Free Locker Mode (with or without Duration of Use Function) In "free locker" operating mode, the user has the option of selecting a free locker and locking it using their data carrier. After the locker has been locked, the user cannot occupy any additional lockers within the same locker group. Only once the original locker has been unlocked can the user lock another locker in the locker group.
GAT ECO.Side Lock 7000 BA / NW BA Operation Locking and unlocking lockers ► Close the locker door and hold it shut. ► Hold the data carrier next to the RFID reading field. o The information on the data carrier is read. ► ► a) Valid data carriers: The LED flashes green briefly and the locking action is carried out. If the duration of use function is enabled, the time on the data carrier is checked and the current time written onto the data carrier.
GAT ECO.Side Lock 7000 BA / NW BA Operation Free Locker Unique Number Mode “Free locker unique number” operating mode differs from the standard free locker mode in the following ways: - All MIFARE and ISO 15693 data carriers can operate with the lock. - The data carrier can have a GANTNER locker segment, however the segment is not used for this mode. - When a locker is locked with a data carrier, the locker number is not written onto the data carrier.
GAT ECO.Side Lock 7000 BA / NW BA Operation Deleting (removing authorization) data carriers When deleting data carriers authorized to use a personal locker, it is only possible to delete all data carriers in the GAT ECO.Side Lock 7000 BA at once. ► Close the locker door and hold it shut. ► Hold the PROGRAM data carrier next to the RFID reading field. ► The GAT ECO.Side Lock 7000 BA enters into programming mode. o The information on the data carrier is read.
GAT ECO.Side Lock 7000 BA / NW BA Operation Locking and unlocking lockers ► Close the locker door and hold it shut. ► Hold the data carrier next to the RFID reading field. o The information on the data carrier is read. The locker number on the data carrier must correspond with the locker number in the lock. ► The following situations are possible.
GAT ECO.Side Lock 7000 BA / NW BA Operation 6.4 GAT ECO.Basic Set B BA The following items are included in the GAT ECO.Basic Set B BA (Part No. 958131). System data carriers: - MASTER data carrier (3 pieces, red) - OPEN MASTER data carrier (optional) - DELETE MASTER data carrier (orange) / formerly RESET data carrier (green) - PROGRAM data carrier (black) - BATTERY data carrier (blue) - SERVICE data carrier (yellow) - Battery cover key for the GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Operation ► Within 5 seconds, hold the first MASTER data carrier next to the reading field. o When the data carrier is read correctly, the LED is green for 2 seconds. ► Remove the MASTER data carrier from the reading field. o The LED flashes green and red alternately. The second MASTER data carrier can now be programmed. ► Repeat the process until all MASTER data carriers are programmed.
GAT ECO.Side Lock 7000 BA / NW BA Operation BATTERY Data Carrier After the battery is replaced in the GAT ECO.Side Lock 7000 BA, the lock is in battery replacement mode and must be returned to the normal operating mode using the BATTERY data carrier. The internal action counter is reset to zero when the BATTERY data carrier is used. See section “4.2.3. Replacing the Battery” for more information. After replacing the batteries of a GAT ECO.
GAT ECO.Side Lock 7000 BA / NW BA Operation 6.7 Signalization Overview The electronics in the GAT ECO.Side Lock 7000 BA are activated by pushing the locker door shut, i.e., when the door shackle is fully inserted into the opening of the lock. This activation is signaled by the LED flashing orange once. Directly thereafter the following lock states are signaled by the LED.
GAT ECO.Side Lock 7000 BA / NW BA Cleaning and Maintenance 7 CLEANING AND MAINTENANCE Risk of damage or failure to the GAT ECO.Side Lock 7000 BA / NW BA - The instructions described in this chapter may only be carried out by suitably trained personnel. - The warnings in this chapter must be observed and followed during functional testing, cleaning, and maintenance. 7.
GAT ECO.Side Lock 7000 BA / NW BA Cleaning and Maintenance ► Hold an authorized data carrier a distance of approximately 1 cm in front of the locker door. o The locker door must unlock and spring open independently. If the door does not spring open by itself, the door must be readjusted (see below). If the data carrier is not read at this distance, the RFID reading field is possibly misaligned and require recalibration (see “4.4 Automatic Antenna Adjustment”).
GAT ECO.Side Lock 7000 BA / NW BA Technical Data 8 TECHNICAL DATA 8.1 Power Supply Power supply: 1 x 3.6 V lithium battery, size AA, capacity 2.4 Ah GANTNER approved battery: EU: Tadiran SL-860/S US: Tadiran TL-4903/S Battery lifetime: Up to 10 years* at +20 °C (68 °F) *depending on usage, configuration, and environmental conditions 8.
GAT ECO.Side Lock 7000 BA / NW BA Technical Data 8.4 Control and Display Elements Control element: Door contact in lock Display element: LED (red / green) to indicate the different operating states 8.5 Interfaces Interface type: USB 2.0 Interface connection: USB type Micro-B 8.6 Housing Material: Plastic (PC), halogen-free, V0 Color: Dark gray Weight: Approx. 400 g (14.1 oz.) Dimensions: 125.2 mm x 100 mm x 25 mm (4.93” x 3.94” x 0.
GANTNER's distribution partner network actively supports customers in over 60 countries. Please visit www.gantner.com Schruns, Austria Houten, Netherlands Sydney, Australia T +43 5556 73784-0 T+31 33 43 284 16 T +61 29011 8114 info@gantner.com info@gantner.nl info-aus@gantner.com London, GB Bochum, Germany Los Angeles, USA T +44 1245 697588 T +49 234 58896-0 T +1 844 703 1139 info-uk@gantner.com info-de@gantner.com info-us@gantner.