Configuration> Operating mode> General> AutoUnlock after locking active
Next, you have to enter the desired time after a locking here:
Configuration > Operating mode > General > AutoUnlock after locking [min]
Enter the time in minutes. The unlocking countdown therefore begins after each lock has been performed. For
example, a value of "300" means that the lock will be automatically unlocked 5 hours after each time it is
locked. If this function is activated, a value must be entered.
NOTE! For the automatic unlocking function, ensure that the correct time is set in the GL7p so that the automatic
unlocking occurs at the correct time. Please note that the GL7p does not consider changes between summer and
winter times.
5.4.4 Duration of Use
Lockers operating in free locker mode can be configured to limit the user to a defined period of use. See section
6.3.1. Free Locker Mode (with or without Duration of Use Function)for detailed information. The duration of use
function is found here:
Configuration > Operating mode > FreeLocker
Select either “Duration” or “Point_of_time” from the “UseTimeLimit” menu for the type of time limit.
Define the time limit in minutes in the “TimeLimit (min)” field.
5.4.5 Locking of Personal Locker without Data Carrier
The functionality of locking personal lockers without data carriers allows the locker to lock automatically when the
locker door is pushed shut, without needing to use a data carrier. The locker can be unlocked again using the data
carrier(s) authorized to use the personal locker. The function is found here:
Configuration > Operating mode > PersonalLocker > PreLock PersonalLocker
Select / deselect the “PreLock Personal Locker” option to turn the function on / off.
5.4.6 RF Standards
The GL7p can operate with data carriers that use ISO 15693, ISO 14443A (MIFARE), and HID iCLASS (13.56 MHz
UID) technology.
The default setting of the GL7p is to operate with ISO 14443A (MIFARE) data carriers.
The setting for the GL7p to operate with ISO 14443A (MIFARE) data carriers cannot be disabled. The setting for the
GL7p to operate with ISO 15693 or HID iCLASS data carriers can be adjusted and is found here:
Configuration > Reader > RF Standards > ISO15693
or
Configuration > Reader > RF Standards > HID
Select / deselect the “ISO 15693” or “HID” option to turn the setting on / off.