Installation Instructions

Table Of Contents
GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Configuration
48
HB_GL7p--EN_12
www.gantner.com
Reader
RF Standards
ISO15693
When set to "True", ISO 15693 data carriers can be read
by the lock
Boolean
False
ISO14443A
When set to "True" ISO 14443 (MIFARE) data carriers ca
be read by the lock. This setting is not configurable.
Boolean
True
HID
When set to "True", the device can read HID iCLASS data
carriers (UID number only)
Boolean
False
Segment configuration
General
SiteKey
Site key of the device. All data carriers must have the
same site key to be used with the device.
Hex
9999
KeySet
DESFire AES keys, encrypted
Hex
MIFARE Classic
Options for reading MIFARE Classic data carriers
SectorNum
The segment where UID data is stored
Integer
4
ReadKey
Select the Read Key (Key A or Key B)
List option
WriteKey
Select the Write Key (Key A or Key B)
List option
MIFARE DESFire
Options for reading MIFARE
DESFire data carriers
ReadKeyNum
Number of the “Read Key”
Integer
WriteKeyNum
Number of the “Write Key”
Integer
ApplicationId
ID of the target DESFire application
Text
EncryptionMode
Select the type of encryption mode
List option
FileNum
File number to read data from
Integer
FileCommMode
File communication mode:
“Plain”, “Maced”, “Enciphered”
List option
FileType
Type of file:
“Standard”, “Backup”
List option
FileDataOffset
Data offset in the DESFire locker file
Integer
0
ISO15693
Options for reading ISO 15693 data carriers
GeneralBlockNum
The segment where general data is stored
Integer
13
CertificateBlockNum
The segment where certificate data is stored
Integer
15
LockerBlockNum
The segment where locker data is stored
Integer
19
Gantner.Connect
FileId
ID number for Gantner.Connect.
Integer
1
BLE
General
BLE enabled
Option to enable/disable the wireless interface for
GL7p.2xxx and GL7p.3xxx locks
Boolean
False
KeySet BLE
Custom key for the wireless interface
GANTNER standard = 0
Hex
BLE advertise timeout idle mode
Time to detect the wireless interface in idle mode. Input in
100 ms (e.g. 600 = 1 minute). Idle mode begins after
activation mode has expired. If you enter "0", idle mode is
active indefinitely
Integer
600
BLE pulse period idle mode
Period between radio pulses in idle mode. Input in 100 ms
(e.g. 600 = 1 min.). As each pulse requires energy, the
period should be set so large depending on the
application that wireless signals are still detectable
Integer
20
BLE advertise timeout activation
Time to detect the wireless interface in activation mode
(after pressing the button). Input in 100 ms (e.g. 600 = 1
min.). When activation mode is over, idle mode starts. If
you enter "0", activation mode is active indefinitely and
idle mode is not used
Integer
150