GL7p - Battery-powered, door-mounted electronic locker lock GL7p
Operation
www.gantner.com
HB_GL7p--EN_12
55
6.3.3 Free Locker Unique Number Mode
“Free locker unique number” operating mode differs from the standard free locker mode in the following ways:
- All MIFARE and ISO 15693 data carriers can operate with the lock.
- The data carrier can have a GANTNER locker segment, however the segment is not used for this mode.
- When a locker is locked with a data carrier, the locker number is not written onto the data carrier.
- Every data carrier can use (lock) any number of lockers at the same time.
Locking and unlocking lockers with a data carrier
► Close the locker door.
► Press the button of the GL7p in using a data carrier for approximately 1 second.
o The information on the data carrier is read.
a) Valid data carrier: The LED flashes blue briefly and then green and the action (lock/unlock) is carried out.
b) Invalid data carrier: The LED flashes blue briefly and then red and the GL7p switches off without completing
the locking action.
► When locking the locker, check that it is locked by pulling the locker door.
Locking and unlocking lockers with a PIN code
► Close the locker door.
► Enter your PIN code.
NOTE: The length of the PIN code can be defined in the configuration.
► Press the OK button (✓) or the button of the GL7p to confirm the PIN code.
o The PIN code is checked.
a) Valid PIN code: The LED flashes green briefly and the action (lock/unlock) is carried out.
b) Invalid PIN code: The LED flashes red briefly and the GL7p switches off without completing the locking
action.
► When locking the locker, check that it is locked by pulling the locker door.