Installation Instructions

GAT NET.Lock 7020 System
Installation
www.gantner.com
HB_GAT-NETLOCK7020--EN_12
21
3.
INSTALLATION
Risk of damage or failure to the GAT NET.Lock 7020
- Read the information in this chapter carefully before installing the GAT NET.Lock 7020
- The GAT NET.Lock 7020 must be installed in a dry place, protected from rain and dripping water
- Carefully observe the measurement diagrams
- Use the correct tools to install the GAT NET.Lock 7020
- The existing GAT NET.Lock Bolt Set 7000 cannot be used with the GAT NET.Lock 7020
3.1
Target Group
This chapter provides information for technicians who install the GAT NET.Lock 7020. Experience in mechanical work
and basic electrical knowledge is required. Previous knowledge of the GAT NET.Lock 7020 is not required.
- In case of damage due to non-observance of the installation and assembly instructions, as well as the use of
non-original accessories, the warranty is void.
- Alteration and/or modification of the product is not permitted.
NOTE!
- The installation instructions in this chapter apply for all variants (see 2.6 System Components”) of the GAT
NET.Lock 7020.
- Where not indicated, all measurements in the diagrams are in millimeters with inches shown in brackets.
3.2
Test Installation
As the GAT NET.Lock 7020 is suitable for a wide range of installation applications, always perform a test installation
including functional testing of the GAT NET.Lock 7020 in a sample locker from the facility before starting the mass
production of lockers.
Ensure that the following important points are met.
- The door shackle slides centrally into the opening of the GAT NET.Lock 7020.
- The locker door locks without any problems.
- The locker door opens without resistance (ensure retaining elements such as springs are correctly calibrated).
NOTE! Ensure the connection cable is completely installed, fed out of the locker body and connected to the GAT
NET.Controller S 7020 before completing the locking test.
Also test the GAT NET.Lock 7020 using a data carrier, ideally of the same type to be used in the locker system, to
ensure the data carrier functions as required. Once the test installation is successfully completed, the remaining locks
can be installed in the same way. An installation checklist is available from GANTNER to assist with the test installation
process.