INSTRUCTION MANUAL WITH
Thank you for your purchase of this product. Before operating this product, please read this instruction manual carefully. After you have read this manual, store it in a safe place for future reference. CONTENTS PRODUCT FEATURES..................................................................................... EG-2 SAFETY PRECAUTIONS.................................................................................. EG-3 PART NAMES........................................................................
(2) Do not place the camera in the following locations. SAFETY PRECAUTIONS 1 Locations subject to extremely high or low temperatures. (Operating temperature range: -10°C to +50°C {14°F to 122°F}) (Storage temperature range: -20°C to +60°C {-4°F to 140°F}) 2 Locations subject to high levels of humidity and dust. (Operating humidity range: max 85% {No condensation}) (Storage humidity range: max 95% {No condensation}) 3 Locations where there are large amounts of water vapor and steam.
Camera body interior PART NAMES Exterior Surface mount cover 1 Lens Body cover 4 Menu Operation Switch Inner cover 5 Video output connector for service monitor 2 Focus/ View angle adjustment lever 7 Termination resistance switch (with communication function) 8 B/W Fix terminal/Mode Selection terminal 3 Power input terminal Video relay cable Camera body Dome cover Accessories Service monitor cable 9 RS485 communication terminal (with communication function) 6 Video relay cable Ad
Attaching to the surface of the ceiling or wall INSTALLATION AND ADJUSTMENT Attaching the unit You can use the following three methods to attach the unit. Please use the method that best fits the conditions of the area in which you want to install the unit. Attaching to the surface of the ceiling or wall This section explains how to install the unit where cables are running through the interior of the ceiling or wall.
Running cables on the exterior surface of the ceiling or wall To run cables on the exterior surface of the ceiling or wall, use the following procedure to attach the camera body. 1 Remove the surface mount cover from the camera body. Embedding in the ceiling or wall Be sure to use the adapter ring when embedding the unit in the ceiling or wall. 1 Hold the body cover and turn the surface mount cover in a counter-clockwise direction until you hear a click.
Attaching to a 4S junction box Be sure to use the adapter ring to attach the camera body when embedding it in the 4S junction box. 1 Attaching the adapter ring Attach the adapter ring to the 4S junction box. Please use screws that are suitable for the 4S junction box. Connecting the cables 1 Connect the power cable. While using 12 V DC, connect the positive (+) side to “+12 V DC.” 12V DC connection 24V AC connection Do not tighten the screws to the extent that the adapter ring is bent.
B/W Fix terminal/Mode Selection terminal This terminal can be used as a B/W Fix terminal and also as a Mode Selection terminal that enables the dynamic switching of OSD settings. The mode selection setting needs to be adjusted beforehand on the OSD setting screen. The picture mode can be fixed at B/W by shorting the two contacts on the B/W Fix terminal.
Attaching the service monitor Use the service monitor cable to check and adjust camera direction, focus, and angle on a service monitor. 2 When you have finished adjusting the direction of the lens, tighten the locking screw with a screwdriver. The service monitor is not supplied in the cell. Please have one ready.
Easy focus adjustment Please make sure to adjust focus in a bright light environment. With the OSD screen not displayed, activate the focus adjustment screen by pressing and holding down the Menu Operation Switch in the UP direction (Jump function). You can also activate the focus adjustment screen by selecting “Setup” “EZ Focus” on the OSD menu. The lens iris is forcibly kept open while this screen is being displayed.
SPECIFICATIONS Model No. Focal length Max. aperture ratio Iris TV system Scanning system Image sensor Effective pixels Scanning frequency Video output Horizontal resolution Angle of view (Wide to Tele) Min. Illuminance F1.3 Night mode AGC Extreme S/N ratio Gamma characteristic Sync.
Digital Day/Night model ZC-D5212NXA Model No.