Manual
Table Of Contents
- Introduction
- Getting Started
- VCA Feature Packages
- Accessing VCA Configuration
- Activation
- Obtaining an Activation Code
- Applying an Activation Code to a Unit
- Switching VCA On and Off
- Enabling Metadata Streaming
- Configuration of Zones and Rules
- Customizing the Tracking Display
- Creating Detection Zones and Lines
- Creating a Zone or Line
- Non-Detection Zones
- Detection Rules
- Object Presence
- Object Direction
- Object Enter and Exit
- Object Appear and Disappear
- Object Dwell
- Object Stopped
- Object Class
- Object Tailgating
- Object Speed
- Object Color Filter
- Counting Line
- Camera Calibration
- Calibration Page Elements
- Calibrating a Camera
- Advanced Calibration Parameters
- Vertical Field of View
- Measurement Units
- Object Classification
- Logical Rules
- Adding and Removing Logical Rules
- Editing Logical Rule Clauses
- Editing Logical Rule Actions
- Clause Types
- Action Types
- Counters
- Creating Counters
- Assigning Rules to Counters
- Counter Storage and Reporting
- Counter Database Service
- Counter Reporting Service
- Email Notification
- Enable Email Notification
- Adding a New Email Notification Recipient
- Email Configuration
- Name
- Description
- Email Address
- Schedule Configuration
- Current Device Time
- Enable Hourly Report
- Trigger Time
- Weekday
- Enable Daily Report
- Trigger Time
- Weekday
- Enable Weekly Report
- Trigger Day
- Trigger Time
- Enable Monthly Report
- Trigger Day
- Trigger Time
- Report Configuration
- Time
- Report All Data
- Time Range
- Counter ID
- Table (Sampling)
- Sorting Order
- Value Type
- Format
- Send Test Report
- Importing Data into Microsoft Excel
- Other Reports
- Heatmap Reporting
- Events Reporting
- Tracks Reporting
- Tamper Detection
- Scene Change Detection
- Burnt-in Annotation
- PTZ Profiles
- PTZ Control Element
- Configure a PTZ Preset
- Create VCA Profile
- Delete VCA Profile
- Disable PTZ Preset
- PTZ Configuration and Auto-Tracking
- PTZ General Configuration
- PTZ Auto-tracking Configuration
- Importing & Exporting VCA Configuration
- Generating External Event Notifications
- Advanced VCA Settings
- Alarm Holdoff Time
- Measurement Units
- Metadata Format
- Event
- Object
- Counting
- Do not send empty metadata packets
- Blob
- Tamper Diagnostics
- Counting Line Diagnostics
- Scene Change Diagnostics
- More Information
- Stationary Object Hold-on Time
- Tracking Options
- Minimum Tracked Object Size
- Display Options
- Minimum Alarm Object Display Time
- Minimum Object Display Time
- Detection Point of Tracked objects
- People Tracker
05-2018-A
Ganz GXi Series VCA Interface Manual V3.05.31.18
47 | P a g e
Logical Rules
Logical rules extend the standard rules system to allow various inputs to be combined using logical
expressions. A logical rule is defined by one or more clauses that determine whether the rule is triggered
or not. The clauses can be thought of as logical components like 'and' or 'not' but can also manipulate
events from other clauses in different ways. The clauses can take input from each other, but there is
always one top level clause that determines the overall output for the rule.
In addition to the clauses that define it, each logical rule also has actions which determine what happens
when the rule is triggered.
Topics in this section:
• Adding and Removing Logical Rules
• Editing Logical Rule Clauses
• Editing Logical Rule Actions Clause Types
• Action Types
Adding and Removing Logical Rules
Logical rules can be added using the 'Logical Rules' tab on the Zones and Rules web page. The list
shows the logical rules that are currently configured. Logical rules can be added, removed or modified
using the buttons at the bottom of the page.
When adding or modifying a logical rule, a window opens to allow the logical rule to be configured. At the
top of this window, basic properties such as the name and description can be set. The rule id is shown in
square brackets to the left of the rule name.