Manual
Table Of Contents
- Introduction
- Getting Started
- VCA Feature Packages
- Accessing VCA Configuration
- Activation
- Obtaining an Activation Code
- Applying an Activation Code to a Unit
- Switching VCA On and Off
- Enabling Metadata Streaming
- Configuration of Zones and Rules
- Customizing the Tracking Display
- Creating Detection Zones and Lines
- Creating a Zone or Line
- Non-Detection Zones
- Detection Rules
- Object Presence
- Object Direction
- Object Enter and Exit
- Object Appear and Disappear
- Object Dwell
- Object Stopped
- Object Class
- Object Tailgating
- Object Speed
- Object Color Filter
- Counting Line
- Camera Calibration
- Calibration Page Elements
- Calibrating a Camera
- Advanced Calibration Parameters
- Vertical Field of View
- Measurement Units
- Object Classification
- Logical Rules
- Adding and Removing Logical Rules
- Editing Logical Rule Clauses
- Editing Logical Rule Actions
- Clause Types
- Action Types
- Counters
- Creating Counters
- Assigning Rules to Counters
- Counter Storage and Reporting
- Counter Database Service
- Counter Reporting Service
- Email Notification
- Enable Email Notification
- Adding a New Email Notification Recipient
- Email Configuration
- Name
- Description
- Email Address
- Schedule Configuration
- Current Device Time
- Enable Hourly Report
- Trigger Time
- Weekday
- Enable Daily Report
- Trigger Time
- Weekday
- Enable Weekly Report
- Trigger Day
- Trigger Time
- Enable Monthly Report
- Trigger Day
- Trigger Time
- Report Configuration
- Time
- Report All Data
- Time Range
- Counter ID
- Table (Sampling)
- Sorting Order
- Value Type
- Format
- Send Test Report
- Importing Data into Microsoft Excel
- Other Reports
- Heatmap Reporting
- Events Reporting
- Tracks Reporting
- Tamper Detection
- Scene Change Detection
- Burnt-in Annotation
- PTZ Profiles
- PTZ Control Element
- Configure a PTZ Preset
- Create VCA Profile
- Delete VCA Profile
- Disable PTZ Preset
- PTZ Configuration and Auto-Tracking
- PTZ General Configuration
- PTZ Auto-tracking Configuration
- Importing & Exporting VCA Configuration
- Generating External Event Notifications
- Advanced VCA Settings
- Alarm Holdoff Time
- Measurement Units
- Metadata Format
- Event
- Object
- Counting
- Do not send empty metadata packets
- Blob
- Tamper Diagnostics
- Counting Line Diagnostics
- Scene Change Diagnostics
- More Information
- Stationary Object Hold-on Time
- Tracking Options
- Minimum Tracked Object Size
- Display Options
- Minimum Alarm Object Display Time
- Minimum Object Display Time
- Detection Point of Tracked objects
- People Tracker
05-2018-A
Ganz GXi Series VCA Interface Manual V3.05.31.18
71 | P a g e
Predefined Requests
The counter reporting service has several pre-defined requests that reflect the most common usage
scenarios. It's possible to just select one of these pre-defined requests and click one of the reporting
modes directly to generate a report in a very short amount of time.
The requests available are:
Predefined Request
From
To
Default Sampling Period
One hour
now - 1 hour
now
1 minute (Table 0)
Today
today @ 0:00
now
10 minutes (Table 1)
Yesterday
yesterday @ 0:00
today @ 0:00
10 minutes (Table 1)
One day
now - 1 day
now
10 minutes (Table 1)
This week
Sunday @ 0:00
today
60 minutes (Table 2)
Last week
Last Sunday @ 0:00
Last Saturday @ 24:00
60 minutes (Table 2)
One week
now - 1 week
now
60 minutes (Table 2)
This month
1st of this month
now
1 day (Table 3)
Last month
1st of last month
Last day of last month
1 day (Table 3)
In each case, the predefined queries populate the rest of the fields on the page, so it's simple to use a
predefined query and then change just a couple of fields to customize it.
Command Request
In addition to using the predefined requests it's possible to select all query parameters manually to query
any combination of data. The options available are described in the following section.
Time
The time bounds of the query. Specify the from and to times in the fields provided. The syntax is as
follows:
Option
Details
Example