Manual
Table Of Contents
- Introduction
- Getting Started
- VCA Feature Packages
- Accessing VCA Configuration
- Activation
- Obtaining an Activation Code
- Applying an Activation Code to a Unit
- Switching VCA On and Off
- Enabling Metadata Streaming
- Configuration of Zones and Rules
- Customizing the Tracking Display
- Creating Detection Zones and Lines
- Creating a Zone or Line
- Non-Detection Zones
- Detection Rules
- Object Presence
- Object Direction
- Object Enter and Exit
- Object Appear and Disappear
- Object Dwell
- Object Stopped
- Object Class
- Object Tailgating
- Object Speed
- Object Color Filter
- Counting Line
- Camera Calibration
- Calibration Page Elements
- Calibrating a Camera
- Advanced Calibration Parameters
- Vertical Field of View
- Measurement Units
- Object Classification
- Logical Rules
- Adding and Removing Logical Rules
- Editing Logical Rule Clauses
- Editing Logical Rule Actions
- Clause Types
- Action Types
- Counters
- Creating Counters
- Assigning Rules to Counters
- Counter Storage and Reporting
- Counter Database Service
- Counter Reporting Service
- Email Notification
- Enable Email Notification
- Adding a New Email Notification Recipient
- Email Configuration
- Name
- Description
- Email Address
- Schedule Configuration
- Current Device Time
- Enable Hourly Report
- Trigger Time
- Weekday
- Enable Daily Report
- Trigger Time
- Weekday
- Enable Weekly Report
- Trigger Day
- Trigger Time
- Enable Monthly Report
- Trigger Day
- Trigger Time
- Report Configuration
- Time
- Report All Data
- Time Range
- Counter ID
- Table (Sampling)
- Sorting Order
- Value Type
- Format
- Send Test Report
- Importing Data into Microsoft Excel
- Other Reports
- Heatmap Reporting
- Events Reporting
- Tracks Reporting
- Tamper Detection
- Scene Change Detection
- Burnt-in Annotation
- PTZ Profiles
- PTZ Control Element
- Configure a PTZ Preset
- Create VCA Profile
- Delete VCA Profile
- Disable PTZ Preset
- PTZ Configuration and Auto-Tracking
- PTZ General Configuration
- PTZ Auto-tracking Configuration
- Importing & Exporting VCA Configuration
- Generating External Event Notifications
- Advanced VCA Settings
- Alarm Holdoff Time
- Measurement Units
- Metadata Format
- Event
- Object
- Counting
- Do not send empty metadata packets
- Blob
- Tamper Diagnostics
- Counting Line Diagnostics
- Scene Change Diagnostics
- More Information
- Stationary Object Hold-on Time
- Tracking Options
- Minimum Tracked Object Size
- Display Options
- Minimum Alarm Object Display Time
- Minimum Object Display Time
- Detection Point of Tracked objects
- People Tracker
05-2018-A
Ganz GXi Series VCA Interface Manual V3.05.31.18
72 | P a g e
Absolute date and time
YYYY/MM/DD hh:mm
2011/10/21 09:00
Seconds
Decimal integer
3600 (=1 hour)
Now
The current time
Now means 2011/10/21 09:00
Today
0:00 on the current day
Today means 2011/10/21 0:00
Yesterday
0:00 on the day before today
Yesterday means 2011/10/20 0:00
Sunday, Monday,
Any day of the week @ 0:00
Thursday means 0:00 on the previous
Thursday
This week
0:00 on the first day of the week
This week means 0:00 on the previous
Sunday
Last week
0:00 on the first day of last week
Last week means 0:00 on the Sunday
before last
This month
0:00 on the first day of this
month
This month means 0:00 on the first day of
this month
Last month
0:00 on the first day of last
month
Last month means 0:00 on the first day of
last month
Time and dates can also be modified and combined with the simple arithmetic operators + and - to
perform querying relative to predefined keywords. Examples of the use of the operators are as follows;
If the current time is 2011/05/23 14:20 Monday
Example
Meaning
Now
2011/05/23 14:20
Today
2011/05/23 00:00
Now-01:00
2011/05/23 13:20
Today 04:00
2011/05/23 04:00
Today-04:00
2011/05/22 20:00
Yesterday+3600
2011/05/22 01:00
Sunday 06:00
2011/05/22 06:00
Counter ID
Allows specification of which counters are included in the request, can be any one of:
Counter ID
Details
Example
Active
All currently displayed counters
1,4,5,6
All
All counters
0-19
One of 0-19
An individual counter id
1
Table (Sampling)
Specifies the table to query. The sampling interval in minutes is displayed in parentheses.
Sorting Order
Specifies how to order the results returned from the query. Can be one of:
Sorting order
Details
Descending
The newest records are returned first
Ascending
The oldest records are returned first